Delta DVP80EH00T
Delta DVP80EH00T | DVP-EH PLC with 40 inputs and 40 transistor outputs
The Delta DVP80EH00T is a PLC CPU from the original DVP-EH series. It runs on 100–240 V AC and provides 40 digital inputs at 24 V DC and 40 NPN open-collector transistor outputs. Delta’s detailed EH specification lists 15,872 program steps. The CPU can sequence conveyors, packaging machines and sorting equipment with many field signals.
Inputs and transistor outputs
Inputs X0–X47 and outputs Y0–Y47 use octal addressing. X10 follows X7. Check the S/S common against the wiring diagram for the fitted NPN or PNP sensors. An inductive sensor can detect a metal part, a photoelectric sensor can count passing products, and a capacitive sensor can detect the presence of suitable materials. If the machine uses an incremental encoder, check the signal levels and assigned counter inputs against the original project and EH manual.
An active NPN output sinks current to 0 V. The original EH instruction sheet lists 5–30 V DC for the transistor outputs and 0.30 A per point at 40 °C for standard switching. Check current draw and coil suppression when using valves or interposing relays. For a digital run command to a variable frequency drive, check the drive’s input type and common terminal.
For cabinet replacement, mark the C0–C7 output commons, DC load supplies, fuses and protective grounding on the drawings. Record any separate timer relay setting as well.
Programming software and cable
WPLSoft is the first choice for reading, backing up and monitoring an existing EH ladder project. If using ISPSoft, verify that the installed version offers the original EH CPU target and configure the serial connection in COMMGR. Keep the original PLC project before conversion. After compiling, review the I/O addresses, counters and instructions that access special modules.
Connect the PC through COM1 RS-232. The DVPACAB2A30 cable has an 8-pin mini-DIN connector at the PLC and DB9 at the PC. For a USB-only PC, use a compatible USB-to-RS-232 adapter and driver. Select the COM number shown in Device Manager.
If an HMI, drive or SCADA system uses Modbus over COM2 RS-485, record the station address, baud rate, parity and ASCII or RTU setting from the existing system.
Related Delta models
The DVP80EH00R is the same-generation model with 40 inputs and 40 relay outputs. The DVP64EH00T provides 32 inputs and 32 transistor outputs. The DVP80EH00T2 belongs to EH2, and the DVP80EH00T3 belongs to EH3. When selecting a replacement, check terminals, high-speed output assignments, expansion modules and project compatibility. For analog measurements, check the signal range and channel settings of the DVP04AD-H module.
Editor’s Note
When buying used, ask for photos of the full side label and the terminals. The full model code is DVP80EH00T.
If BAT.LOW is on, back up the program and retentive registers before a planned shutdown and battery replacement. Follow Delta’s battery procedure.
Once power is isolated, photograph the wire numbers at S/S and the output commons before removing field wires.
On the bench, disconnect the machine loads and check each output group with a suitable DC test load. When troubleshooting the PLC, check terminal and load response as well as the Y LED.
Before returning the machine to production, verify the safety relay and emergency-stop circuit against the cabinet drawings.
Related topics and internal references
Industrial communications · Delta DVP PLC files · ISPSoft User Manual (English PDF)
Delta DVP-EH · Delta DVP PLC series · Delta main page
External references
Delta DVP-EH installation and wiring sheet (2006, PDF) · Delta DVP technical information and original EH model table (PDF) · Delta WPLSoft and ISPSoft FAQ