Delta DVP80EH00T3
Delta DVP80EH00T3 | 40 inputs, 40 transistor outputs and 4 pulse axes
The Delta DVP80EH00T3 is a 100–240 V AC main unit in the DVP-EH3 series. It has 40 digital inputs rated at 24 V DC and 40 NPN open-collector transistor outputs. In labeling, cut-to-length and indexing machines, the PLC reads sensors and issues motion commands. The PLC CPU runs the machine sequence.
Digital I/O and panel wiring
The X0–X47 inputs and Y0–Y47 outputs use octal addressing. X10 follows X7. When checking PLC inputs and outputs, match the project address to the cabinet terminal. When adding an inductive sensor, check its PNP or NPN type and follow the Delta diagram for the sink/source connection to S/S.
Each transistor output switches a suitable DC load through its common terminal. Check output current, common groups and load suppression when connecting a coil or interface relay. Check the DIN rail layout and protective grounding during cabinet installation. For analog I/O, select an expansion module that matches the signal and CPU, such as the DVP04AD-H3 for analog inputs.
High-speed counters and 200 kHz pulse outputs
Delta specifies four high-speed counter channels and four pulse-output axes rated up to 200 kHz. The high-speed counter input pairs are X0/X1, X4/X5, X10/X11 and X14/X15. Check the count mode and signal level when using an incremental encoder. An encoder with differential line-driver outputs requires a suitable electrical interface.
The manual lists the high-speed pulse outputs as CH0 Y0/Y1, CH1 Y2/Y3, CH2 Y4 and CH3 Y6. Match the pulse and direction terminals to the selected instruction and the servo drive input mode. The PLC sends the pulse command. The drive powers the servo motor.
Programming software and cables
Use WPLSoft to read, back up and monitor the existing ladder program. ISPSoft also supports the EH3 target. In ISPSoft, use COMMGR to configure the connection. Confirm the CPU target, software version and instruction support before writing the PLC program.
For COM1 (RS-232), use UC-PRG020-12A with a USB-equipped PC or UC-MS020-01A with a native RS-232 port. Install the USB cable driver and select the COM port assigned by Windows. For Modbus communication with an HMI or drive over COM2 (RS-485), match the station address and the serial settings at both ends. Delta PLC cable options
Related Delta models
The DVP80EH00R3 has the same I/O count with relay outputs. The DVP64EH00T3 has 32 inputs and 32 transistor outputs, while the DVP48EH00T3 has 24 of each. Consider the DVP32EH00M3 for applications that need differential signals on specific channels. The DVP04AD-H3 adds analog inputs.
Editor’s note
When buying used, match the full nameplate code to the quotation. Look closely at the T3, R3 and T2 suffixes.
Before removing the old unit, save the PLC project, communications settings, drive pulse mode and electronic gearing values.
After testing the regular I/O on the bench, check the high-speed counter and pulse channels the machine uses.
If an output LED is on and the axis stays still, check the PLC signal type, drive pulse input and common connections together.
For the first movement test, put the machine in a safe test condition. Check the direction and commanded travel at low speed.
PDFs and internal references
Delta DVP PLC files · DVP-EH3 series · Delta DVP PLC series
External references
DVP-EH3 installation and terminal diagrams · DVP-PLC programming manual · Delta Cable Selection Guide, section 1.10