Delta DVP80EH00T2
Delta DVP80EH00T2 – EH2 PLC with 40 inputs and 40 transistor outputs
The Delta DVP80EH00T2 is a Delta DVP-EH2 PLC main unit with a 100–240 V AC supply, 40 digital inputs and 40 NPN open-collector transistor outputs. This 16K-step class CPU brings a large number of field signals into one unit for conveyors, packaging and multi-station machines.
I/O addresses and common terminals
The built-in digital inputs and outputs use the octal address ranges X0–X47 and Y0–Y47. Check the 24 V DC input circuit when wiring inductive sensors or limit switches. Wire the S/S input common to suit the PNP or NPN circuit. Identify the C output commons on the terminal diagram and protect the load supply with suitable fusing.
200 kHz counter inputs and 10 kHz outputs
Delta’s EH2 instruction sheet rates X0/X1 and X4/X5 for input signals up to 200 kHz. For this model, the sheet lists 20 kHz for X10/X11 and X14/X15. With an incremental encoder, check the A/B counting mode, terminal assignment and frequency limit together. If the encoder uses a differential line-driver output, also verify the receiving circuit.
The Y outputs are standard 10 kHz-class transistor outputs. The 200 kHz rating on this unit applies to counter inputs. For pulse control of a servo drive or stepper motor drive, check the pulse frequency required and the instruction supported by the PLC. For a servo motor axis, include the drive’s electronic gearing when calculating the required pulse rate.
Programming software and cable
Use WPLSoft to read, edit and monitor an existing ladder program. In ISPSoft, select the EH2 PLC project target and the serial channel created in COMMGR. Keep a copy of the original project before converting it.
Programming uses COM1 RS-232, 8-pin mini-DIN. A PC with a physical serial port can use a DVPACAB230-type Delta PLC cable. On a USB-equipped PC, pair it with a compatible USB-to-RS-232 adapter. Install the driver, select the COM port assigned by Windows and match the existing serial settings.
COM2 RS-485 is the built-in field communications port. On an RS-485 Modbus line, match ASCII or RTU mode, station address and serial settings with the panel and field devices.
Related Delta models
The DVP80EH00R2 has the same 40 inputs and 40 outputs with relay switching. The DVP64EH00T2 is an EH2 with 32 inputs and 32 transistor outputs. The DVP40EH00T2 has 24 inputs, 16 transistor outputs and 200 kHz pulse support on designated Y terminals. The DVP80EH00T3 is the EH3 model with 40 inputs and 40 transistor outputs. It offers a 30K-step program capacity and up to 200 kHz pulse output on four axes. Before replacing a CPU, check the terminal layout, project target and expansion modules together.
Editor’s Note
Read the T2 suffix on the label. When buying used, ask for photos of the full model code and output terminals. Models with the same 80-point housing use different output types.
Test outputs one group at a time. Check the terminal with a suitable test load while the Y LED is on. If several outputs in a group fail together, measure at the common terminal as well.
Test the counter with a real signal. Turn the encoder in both directions and verify direction and counts per revolution. If it misses pulses, check the X terminal pair and input mode first.
Back up the program and data. If BAT.LOW is on, save the program, required retained values and serial settings before working on the battery.
If counting goes wrong when the motor starts, check grounding, encoder cable routing and electromagnetic interference. Measuring at the PLC terminals helps identify problems along the field wiring.
Internal references and PDFs
Related topics · Delta DVP PLC series · Delta PLC · Used Delta equipment
External references
Delta DVP-EH2 instruction sheet, 5011668905-EH27 · Delta DVP-PLC programming manual, §2 · Delta DVP catalogue, EH2 model table and accessories