Delta DVP64EH00T2

Delta DVP64EH00T2 PLC | 32 Inputs, 32 NPN Transistor Outputs

The Delta DVP64EH00T2 is a 100–240 V AC PLC CPU in the DVP-EH2 series. It has 32 digital inputs at 24 V DC and 32 NPN open-collector transistor outputs. In a conveyor, packaging machine or multi-station machine, it can read inductive sensors and photoelectric sensors and switch 24 V DC field loads through suitable output circuits.

Digital I/O and cabinet wiring

The built-in PLC inputs and outputs use octal addresses. Inputs run from X0–X37 and outputs from Y0–Y37. Check the S/S common and sink/source wiring for the PNP or NPN sensors in use. Use the terminal diagram to check the common for each DC output group. For a pressure or level transmitter, choose an analog input module that matches the signal type. Delta’s EH2 catalogue lists 16,000 program steps and 10,000 data-register words.

High-speed counter inputs and pulse outputs

Delta’s EH2 instruction sheet lists X0/X1 and X4/X5 as 200 kHz input pairs on the 64EH2 and X10/X11 and X14/X15 as 20 kHz pairs. With an incremental encoder, check the limit for the selected A/B counting mode. If you use a differential line-driver encoder, match its electrical interface to the PLC input type.

Delta lists the DVP64EH00T2’s onboard transistor outputs in the 10 kHz class. When using a pulse output to position a servo motor, check the required frequency and the servo drive’s pulse input type. Use a CPU or positioning module rated for 200 kHz output when the application requires it.

Programming software and cable

Use WPLSoft to read the existing Ladder program from the PLC to the PC and save a backup. If you use ISPSoft, check that your installed release offers the EH2 target and start the serial driver in COMMGR. For the programming connection, select the assigned Windows COM port and match the PLC’s serial settings.

Connect the PC to COM1 RS-232. Delta documents the DVPACAB2A30 programming cable. If the PC has no DB9 port, use a compatible USB-to-RS-232 adapter on the PC end and install its driver. See Delta PLC cables for other connection options.

COM2 RS-485 is available for industrial communications. For Modbus RTU, match the station address, baud rate, parity and stop bits at both ends. Before a CPU swap, record the existing serial settings and the part number of any installed option card.

Related Delta models

DVP64EH00R2 has the same I/O count and relay outputs. DVP80EH00T2 has 40 inputs and 40 transistor outputs. DVP40EH00T2 is one of the EH2 models with 200 kHz pulse output. DVP64EH00T3 offers the same I/O count in the EH3 family. Before moving to EH3, compare program instructions, high-speed channel assignments, terminal layouts and expansion cards.

Editor’s Note

When buying used, ask for clear photos of the side label and terminals. The T2 suffix identifies the transistor-output EH2 model.

Back up the program and required data through COM1 first. If BAT.LOW is on, follow Delta’s battery procedure.

If a Y indicator lights, verify the output with a suitable DC test load. Check the commons group by group and disable machine motion for the test.

When an encoder gives trouble, first check the A/B input pair and confirm that the expected frequency is within that pair’s limit.

If the count becomes erratic when a drive starts, inspect the cable route, sources of electromagnetic interference and cabinet grounding.