Delta DVP80EH00R2

Delta DVP80EH00R2 – PLC with 40 inputs and 40 relay outputs

The Delta DVP80EH00R2 is a Delta DVP-EH2 PLC CPU with a 100–240 V AC supply, 40 digital inputs at 24 V DC (X0–X47) and 40 relay outputs (Y0–Y47). Addresses use octal numbering, so X10 follows X7. Delta lists 16K program steps and 10K words of data registers for EH2. Typical applications include conveyors, packaging equipment and assembly machines with multiple sensors and auxiliary loads.

Inputs, encoder signals and relay loads

Check the CPU supply and field input circuit separately. Match the S/S input common to the PNP or NPN sensor and follow Delta’s diagram for the required sink/source arrangement. An inductive sensor can detect metal, a photoelectric sensor can detect passing products and a limit switch can report end-of-travel. Match the NO/NC contact action to the condition in the program.

Delta’s 2014 instruction sheet lists 200 kHz input bandwidth for X0, X1, X4 and X5. On this CPU, X10, X11, X14 and X15 are 20 kHz inputs. For an encoder, check the counter mode, A/B phases and electrical output type. Use a compatible Delta DVP-EH expansion module when a 0–10 V or 4–20 mA analog input is required.

The relay outputs are rated at 2 A per point and 5 A per common for resistive loads. Check coil inrush, suppression and fuse selection for contactors and solenoids. Follow panel protective grounding requirements and route signal wiring away from power cables.

Programming software and cable

Program the CPU with Delta WPLSoft or Delta ISPSoft. When programming the PLC, select the EH2 CPU target. Keep the existing ladder diagram project together with the software version and CPU firmware details. For ISPSoft, start the serial channel in COMMGR and select that channel in ISPSoft.

Connect to the PLC’s 8-pin mini-DIN COM1 RS-232 port. The DVPACAB215 (1.5 m) or DVPACAB230 (3 m) can be used. For a USB-equipped computer, install the driver for a suitable USB-to-RS-232 adapter and select the assigned COM number. See Delta PLC programming cables for connection options.

RS-485 and related Delta models

COM2 is the RS-485 field port. On a Modbus RS-485 link, match the station address, baud rate, data format and device roles. Check whether the existing project uses Modbus RTU or ASCII. See the RS-232, RS-422 and RS-485 comparison and industrial communication guide for interface selection.

The DVP64EH00R2 has 32 inputs and 32 relay outputs. The DVP80EH00T2 has the same 40 inputs and 40 outputs, with transistor outputs. Delta’s instruction sheet places the 80-point T2 model in the low-speed output group. The DVP80EH00R3 is the later EH3 model with the same I/O count. Compare the program, expansion modules and terminal layout before replacing the CPU.

Editor’s Note

Read the nameplate photo before buying used. Check the complete code and the terminals. Look for heat marks, cracks or loose screws around the output commons.

Back up the program and retained data first. If BAT.LOW is active, verify the backup before battery work. Keep the original engineering project and serial settings.

Check the contacts as well as the relay sound. Isolate power and inspect the terminals. With machine loads disconnected, test each relay group using a suitable test load. See the electrical measurement and test guide.

Check the encoder at operating speed. Monitor the counter at low speed and normal machine speed. Verify the A/B direction as well.

Test the serial ports separately. Read the program through COM1. Then verify data exchange with a field device through COM2.