Delta UT-14SS2-A

Delta UT-14SS2-A — PLC and HMI Starter Training Kit

Delta UT-14SS2-A is a starter kit for learning PLC programming, HMI screen development and digital I/O applications. Its main controller is the DVP14SS211R. This set in the Delta DVP training kit range combines a PLC, operator panel, power supply, simulator and connection components.

The kit code does not identify a PLC alone. Delta’s 2024 kit manual lists the DOP-107BV HMI. Older documentation also shows DOP-B07S410. For used equipment, check the actual panel label and accessories individually; the documented list below does not establish that every offered set is complete.

Contents listed in the 2024 manual

Component Model / contents
PLC DVP14SS211R
HMI DOP-107BV, 7 inch
Power supply DVPPS01 / DVP-PS01 in the manual
PLC programming cable UC-PRG020-12A — 2 m
HMI programming cable UC-PRG015-02A — 1.5 m
HMI–PLC serial cable UC-MS020-06A — 2 m
I/O simulator board 5502577100
Other items DC power cable, RS-485 cable, four HMI screw locks and manual

DOP-107BV belongs to the DOP-100 family, while the older DOP-B07S410 belongs to DOP-B. Select the actual HMI model when developing its project. The 2024 manual removes the USB flash-drive introduction and directs software and example downloads to Delta.

PLC, HMI and power specifications

The DVP14SS211R is a 24 V DC CPU with 8 digital inputs and 6 relay outputs in the DVP-SS2 family. It uses COM1 RS-232 and COM2 RS-485. Do not treat its R-type relay outputs as high-speed transistor pulse outputs for motion control. The basic kit I/O is digital.

DOP-107BV is a 7-inch, 800 × 480 HMI with serial communication and USB project transfer. It has no built-in Ethernet port. The DVPPS01 power supply provides 24 V DC at 1 A / 24 W. Connect mains only to the power supply input and the PLC/HMI to the appropriate DC output. Calculate total load when selecting DVP power supplies.

Programming and communication arrangement

The kit manual uses ISPSoft and COMMGR for its PLC examples. Develop the HMI project with DOPSoft. WPLSoft can be considered separately for supported DVP PLC projects. The PLC program and HMI screen project are separate files targeting different devices.

Use UC-PRG020-12A for PC–PLC access and UC-PRG015-02A for PC–HMI transfer. HMI–PLC serial communication uses UC-MS020-06A or the documented RS-485 arrangement. DVP programming cables and DVP communication cables serve different connections. Match the interface, station address, baud rate and data format for panel communication.

Suitable learning exercises

Build introductory exercises for input monitoring, start–stop logic, timers, counters, relay output control and HMI register reading/writing. Begin with a simple input/output relationship on the simulator, then add an HMI button, indicator and numeric display. Verify operation in the training arrangement before connecting industrial loads.

Difference from UT-12SE-A1

UT-12SE-A1 uses the DVP12SE11R PLC and DOP-107EV HMI, with different hardware for Ethernet training. Do not assume identical port capabilities for UT-14SS2-A’s SS2 PLC and DOP-107BV panel. Review Delta HMI starter kits and Delta DVP PLC series for comparison. DCISoft is used for relevant Ethernet-device settings.

Editor’s Note

A PLC and panel together do not establish a complete kit. Check the simulator board, programming cables, serial cable and panel mounting parts. A missing connection component can turn the first lesson into fault-finding.

Before applying power, identify the mains input and 24 V DC output separately. Avoid an exposed mains arrangement on the bench; complete polarity checks and cable securing first.

Start by monitoring one input and one output. Verify the input common and simulator wiring before loading a larger program. Confirm that the hardware I/O indicator and software address refer to the same point.

A relay click does not prove contact condition under load. Test used PLC outputs individually with a suitable test load; the simulator indicator is not a substitute for an industrial load test.

Keep HMI project transfer separate from PLC programming. Establish the PLC connection first, then verify panel serial communication. An incorrect station address or interface selection can make healthy hardware appear faulty.

If an older set has a different panel, check the target HMI and communication driver before transferring its project. Keep working PLC and HMI backups as separate files, and do not use a factory reset as the first diagnostic step.

PDF, software and related topics

Use the Delta PLC accessories PDF and software files page for the kit manual, application examples and software links. Device documents are also available under Delta PLC and HMI manuals.

Navigation: UT-14SS2-A main page · Delta PLC accessories · Delta PLC models · Used Delta products

External references

Delta Starter Kit Manual — UT-14SS2-A / UT-12SE-A1 · Delta Starter Kit Manual — manufacturer document copy · Delta DVP / TP Catalogue — Starter Kits / DVPPS01 · Delta DOP-107BV Instruction Sheet