Delta DOP-B

Delta DOP-B covers operator panels from several hardware periods in 4.3, 4.7, 5.6, 7, 8, 10.1 and 10.4-inch sizes. Models sharing a display size can differ in resolution, communication, memory, card support and physical keys. Read the full model together with the existing project and rear connections.

This page addresses 33 complete DOP-B codes appearing in manufacturer documents. Serial/Ethernet models, Professional variants, the VGA-input model and early low-resolution panels are distinguished. A code-only reference is not used to assign another model’s full hardware specification.

S, E, PS, PE, K and VS distinctions

The S and PS models compared here have no Ethernet; E and PE models provide one Ethernet interface. PS/PE distinguish Delta’s Professional Integration Function. K models include physical function keys. DOP-B10VS511 provides a VGA input, not an external-monitor output.

These letters alone do not establish the COM count, memory or SD support. B07S410 and B07S411 share a 7-inch resolution but differ in serial channels and memory. The older B07S200 group also has physical keys without a K suffix. Preserve the complete ordering code.

Small displays: B03, B04 and B05

DOP-B03S211 / DOP-B03E211: 4.3-inch, 480 × 272; 118.8 × 92.8 mm cutout. S211 has no Ethernet; E211 provides one Ethernet port. The 2016 table lists COM1 RS-232/RS-485 and COM2 RS-422/RS-485, with no COM3. USB Host and Client are provided; SD support is not listed.

DOP-B04S211: 4.7-inch, 480 × 272; 138 × 93.1 mm cutout. There is no Ethernet, USB Host or SD slot. It provides one USB Client and COM1 with RS-232/RS-422/RS-485 modes. Historical documents specify 4 MB Flash and 8 MB SDRAM. Matching B03S211 resolution does not make the display, cutout or interfaces equivalent.

DOP-B05S100 / DOP-B05S101: 5.6-inch, 320 × 234; 172.4 × 132.4 mm cutout. The 2012 catalogue distinguishes 4 MB Flash for S100 and 8 MB for S101. There is no Ethernet or SD support; USB Host/Client are provided. Assess COM2/COM3 through the shared connector’s pin and operating-mode tables.

DOP-B05S111: 5.6-inch, 320 × 234; 172.4 × 132.4 mm cutout. The 2016 catalogue lists no Ethernet, USB Host/Client and COM1/COM2/COM3 functions. A cutout matching S100/S101 does not establish cable or project interchangeability.

7-inch, 800 × 480 standard and keyed models

DOP-B07S410: 7-inch, 800 × 480; 196.9 × 142.9 mm cutout. The 2016 table lists COM1, 4 MB Flash and USB Client, with no COM2/COM3, USB Host, SD or Ethernet. Do not apply this model’s limited hardware to all B07 panels.

DOP-B07S411 / DOP-B07E411: 7-inch, 800 × 480; 196.9 × 142.9 mm cutout. S411 has no Ethernet; E411 has one Ethernet port. Listed modes are COM1 RS-232, COM2 RS-232/RS-485 and COM3 RS-422/RS-485. USB Host/Client and 128 MB Flash are specified; the 2016 table lists no SD support.

DOP-B07S401K / DOP-B07S411K: 7-inch, 800 × 480; 196.9 × 142.9 mm cutout. The catalogue groups both codes under a shared specification column with eight physical function keys and no Ethernet. That shared column does not prove interchangeability for every project or firmware release. Preserve key assignments and revision details.

DOP-B07S415 / DOP-B07E415: 7-inch, 800 × 480; 196.9 × 142.9 mm cutout. They provide SD/SDHC and USB Host/Client. COM1 is RS-232; COM2 and COM3 list RS-232/RS-422/RS-485. E415 adds Ethernet and stereo audio output.

DOP-B07PS415: a Professional variant in the same 7-inch, 800 × 480 and 196.9 × 142.9 mm cutout class, without Ethernet. Verify the Delta integration functions and application project. The Professional designation does not imply every feature absent from a standard panel is included.

7-inch, 800 × 600 and 8-inch models

DOP-B07S515 / DOP-B07E515: 7-inch, 800 × 600; 172.4 × 132.4 mm cutout. S515 has no Ethernet; E515 provides Ethernet and stereo audio. These 4:3-resolution displays do not use the cutout of 800 × 480 B07S/E411 or 415 models.

DOP-B07PS515: 7-inch, 800 × 600; 172.4 × 132.4 mm cutout. This Professional model has no Ethernet. Its resolution and mechanical dimensions differ from PS415 despite the related function class.

DOP-B08S515 / DOP-B08E515: 8-inch, 800 × 600; 219.4 × 166.5 mm cutout. S has no Ethernet; E provides Ethernet and stereo audio. Sharing a resolution with the 7-inch 515 group does not provide mechanical interchangeability.

10.1-inch and 10.4-inch models

DOP-B10S411: 10.1-inch, 800 × 480; 261.3 × 189.3 mm cutout, without Ethernet or SD support. DOP-B10S615 / DOP-B10E615: the same 10.1-inch and cutout class with 1024 × 600 resolution and SD/SDHC. E615 provides Ethernet and stereo audio; S615 has no Ethernet.

DOP-B10S511 / DOP-B10E515: 10.4-inch, 800 × 600; 285.2 × 210.2 mm cutout. S511 has no Ethernet and no SD support in the 2016 table. E515 provides Ethernet, SD/SDHC and stereo audio. B10 does not identify one universal 10.1-inch display.

DOP-B10VS511: 10.4-inch, 800 × 600; 285.2 × 210.2 mm cutout. It has no Ethernet; the distinguishing feature is an 800 × 600-pixel, 56/60 Hz VGA input. VGA image display and PLC communication are different functions.

DOP-B10PE515: 10.4-inch, 800 × 600; 285.2 × 210.2 mm cutout. It includes Ethernet, SD/SDHC, stereo audio and Delta Professional integration support. Similar naming and housing do not establish full application equivalence with B10E515.

Early low-resolution B07 group and additional codes

DOP-B07S200, DOP-B07S201, DOP-B07S211, DOP-B07E205 and DOP-B07E215: the HB03 quick-start guide specifies 7-inch, 480 × 234 displays and a 196.9 × 142.9 mm cutout. E205/E215 provide Ethernet; the S models do not. Four user keys and four system keys are defined for this group.

The HB03 table identifies CCFL backlighting for B07S200 and LED backlighting for the other four early B07 models. A shared housing size does not establish display technology or project equivalence with later 800 × 480 panels. This distinction matters when servicing the backlight.

DOP-B03S210 and DOP-B07SS411 appear with these exact spellings in the February 2019 transition manual. It maps their projects to DOP-103BQ and DOP-107BV respectively. The double-S SS411 code has not been silently changed to B07S411: B07S411 has a separate row in that table. Neither code is assigned another model’s full hardware specification here.

COM function, physical connector and cable

Some DOP-B models use different pins of one connector for COM2 and COM3. HB03 explicitly identifies a connection in which COM2 RS-232 hardware flow control prevents COM3 use. Three COM labels therefore do not establish three independent physical connectors operating simultaneously in every mode.

For programming and HMC cables, match the actual port table, RS-232/422/485 mode, controller driver, baud rate, parity and station address. Do not select communication peripheral units or Ethernet expansions by connector shape alone. USB Client PC communication and USB Host peripheral connections have different roles.

Screen Editor, DOPSoft 2 and conversion to DOP-100

The historical HB03 document uses the name Delta Screen Editor; later catalogues describe DOPSoft. Identify the panel, OS/firmware and last project-editor version before changing software. Preserve the original project and perform conversion on a copy.

Delta’s official DOP-B FAQ states that DOPSoft v2.00 is no longer updated or downloadable from its download centre. Users requiring program changes on legacy DOP-B hardware are directed to Delta’s contact form. See the official DOPSoft v2.00 FAQ. Use the official Delta download centre and manufacturer support for software supply.

Opening a supported legacy project in DOPSoft 4 converts it to a DOP-100 target. This does not establish DOPSoft 4 programming support for the original DOP-B hardware. Check the new target’s resolution, physical interfaces, audio, printer functions, accounts/passwords, macros and recipes.

The 2019 manual describes partially compatible cases where three physical COM ports on the old panel become two on the replacement. It also specifies COM1-to-COM2 RS-422 remapping for B03S210 → DOP-103BQ and B07S410 → DOP-107BV. Reusing the old port number without checking the new project will not establish communication.

The transition table’s “coming soon” and “no corresponding model” statements describe February 2019. For example, it maps B03E211 to DOP-103WQ, whereas Delta’s later global list directs it to DOP-105CQ. Similarly, the historical lack of a B05S111 replacement does not mean there is no later migration option.

Discontinued models in Delta’s global list

DOP-B03S211 → DOP-103BQ and DOP-B05S111 → DOP-107EG carry April 2019 discontinuation records. DOP-B03E211 → DOP-105CQ carries June 2019.

DOP-B07S411, DOP-B07S401K, DOP-B07S411K, DOP-B07S415 and DOP-B07PS415 → DOP-107CV; DOP-B07E415 → DOP-107EV. These records state May 2019. DOP-B07S515, DOP-B07E515 and DOP-B07PS515 → DOP-107EG carry April 2019 records.

DOP-B08S515 / DOP-B08E515 → DOP-108IG; DOP-B10S615 / DOP-B10E615 → DOP-108IS; DOP-B10S511 → DOP-110CG; DOP-B10E515 → DOP-110IG carry June 2019 records. DOP-B10S411 → DOP-110CS carries May 2019.

These are manufacturer replacement references, not guarantees of matching screen size, cutout, ports or project behaviour. Replacement suggestions involving another display size need a separate mounting assessment. No date or replacement is inferred for DOP-B codes absent from that list. See Delta DOP-100 for the newer family.

Power, mounting and backups

The reviewed documents specify 24 V DC, −10% / +15%: 21.6–27.6 V DC. Consumption differs by model; the 2016 table gives 2.64 W for B03S211 and 12 W for B10S615/E615. Add USB loads and cable voltage drop when selecting shared power supplies; retain Delta’s isolated-supply recommendation.

Cutouts above are nominal width × height. Obtain tolerances, enclosure thickness and fasteners from the exact model drawing. Do not apply the B04S211 mounting-thickness range to larger panels. Review the gasket, rear clearance, cooling and grounding under mounting and power connections. Front-face IP65/NEMA/UL ratings do not mean the rear connection area is waterproof.

The documents list CR2032 lithium backup batteries. Assess the battery, RTC and retained data against the actual project. Preserve the source project, recipes, alarm/history data and communication settings before battery service, factory reset or firmware changes.

Editor’s note

Do not purchase a replacement simply as a “7-inch Delta screen”. B07S201 and B07S411 can share a cutout while using 480 × 234 and 800 × 480 displays. Establish the label, resolution and working project before choosing a replacement.

For a dark display or restarts, check 24 V at the panel under load. Separate loose terminals, USB peripheral loads and cable voltage drop. Do not select LED backlight parts for an early CCFL model such as B07S200.

Test the touch surface at edges and corners, and every fitted physical key. Gasket pressure, overtightened fasteners and a dirty bezel can affect touch response. Hard objects or further tightening are not suitable diagnostic methods.

One readable PLC value does not prove every interface works. Test the COM modes, Ethernet, USB Host/Client and card slot actually provided. Account for shared COM2/COM3 connector functions.

Back up before battery service, firmware changes or factory resets. A used panel showing a demonstration screen does not establish that the machine source project is included. Verify that the source opens and matches the intended target.

A successful DOP-100 compilation does not complete commissioning. Test keys, audio alarms, printing, recipes, user permissions and communication-loss behaviour under controlled conditions. Record RS-422 remapping from COM1 to COM2 and any mechanical adaptation.

Related panels and documents

Earlier panel families are covered under DOP-A, DOP-AE and DOP-AS; large panels under DOP-W; handheld panels under DOP-H07 and DOP-107H. HMC07 and HMC08 require separate assessment of their motion-control functions.

TP text panels, TP04P and TP70P belong to different panel/control groups. Select remote I/O, digital I/O expansions, starter kits and HMI modules/accessories against their own compatibility documents rather than treating them as universal DOP-B accessories.

Use Delta HMI PDF files and Delta PLC and HMI manuals for document selection. Return to Delta HMI families or browse available used Delta products.

Manufacturer documents and external references

The DOP B/H/W catalogue — 2 December 2016 document-code edition compares later DOP-B models on PDF pp.18–19. The DOP-B catalogue — 16 March 2012 includes B04S211, B05S100/S101 and other period models on PDF pp.3, 9–10. Both are distributor-hosted manufacturer documents.

The DOP-B HB03 quick-start guide — 7 May 2009, 5011665703 contains English and two Chinese sections; the six early models are compared on PDF pp.14–15. This file is not labelled as the 30 December 2008 HB02 edition mentioned in the old description. The official B04S211 multilingual instruction record is an additional reference; access may redirect to Delta’s terms/verification page.

The DOP-B to DOP-100 transition manual — February 2019 covers model/project conversion on PDF pp.7–8 and RS-422 remapping on pp.22–24. Compare later replacement references against the Delta global HMI product list. Document dates alone do not establish the beginning or end of the whole DOP-B family.