Delta AS PLC series
The Delta AS PLC series includes CPUs, expansion modules and motion controllers for machine automation. When selecting a CPU, check the onboard I/O, output type and servo network. For a replacement, start with the full model code on the label.
Delta AS PLC PDF files
Archive page for CPU, module and motion control documentation.
Which Delta AS CPU?
Delta AS200
AS228 models have 16 digital inputs and 12 digital outputs. Choose AS228T-A for NPN, AS228P-A for PNP or AS228R-A for relay outputs.
AS218 models have 8 digital inputs, 6 digital outputs, 2 analog inputs and 2 analog outputs. AS218TX-A has NPN, AS218PX-A PNP, and AS218RX-A relay outputs.
Delta AS300
Onboard I/O and function card options depend on the AS300 model. The AS300N-A uses expansion modules for field I/O. The AS320T-B has 8 digital inputs and 12 digital outputs, and the AS332T-A has 16 digital inputs and 16 digital outputs.
For differential pulse outputs, check the channel and frequency ratings of the AS324MT-A.
Delta AS500 motion controllers
For multi-axis servo applications, choose the motion network first. The AS516E-B uses EtherCAT motion control and the AS524C-B uses CANopen DS402.
Check drive compatibility, the number of real axes and the required synchronization cycle together.
I/O, measurement and communication modules
Browse Delta AS expansion modules for digital I/O and analog and measurement modules for 0–10 V, 4–20 mA, RTDs, thermocouples and load cells. See AS specialty modules for positioning and dedicated communication, or AS function cards for CPU-mounted options.
Check the host CPU, slot and power budget when selecting a module. See Delta AS power supplies for supply options.
Programming and commissioning
Check the ISPSoft version for the CPU and the COMMGR settings for the PC connection. CANopen Builder use depends on the CPU, card and network application. See Delta PLC software for tools and version information.
Editor’s Note
When buying used, photograph the CPU and module labels. Keep the full order codes, including their suffixes.
Use the terminal diagram to check whether the field load needs NPN, PNP or relay outputs.
Before changing a CPU, back up the program, hardware order, network settings and axis settings.
For analog modules, compare the signal range, measured input and program scaling.
Before the first servo test, verify the drive pairing and axis direction.