Delta AS200
Delta AS200 compact modular PLC series
The Delta AS200 is part of the Delta AS PLC family for machine and panel control. These CPUs use a 24 V DC supply and have a 64k-step program capacity. Select among the six models by built-in I/O count, output type and analog channel requirements.
AS228 and AS218 CPU models
AS228 – 16 digital inputs and 12 digital outputs. The AS228T-A has NPN transistor outputs, the AS228P-A has PNP transistor outputs and the AS228R-A has relay outputs.
AS218 – 8 digital inputs, 6 digital outputs, 2 analog inputs and 2 analog outputs. The AS218TX-A has NPN transistor outputs, the AS218PX-A has PNP transistor outputs and the AS218RX-A has relay outputs.
Analog measurement and high-speed pulse output
The AS218 has 12-bit built-in analog channels. Input modes are ±10 V, ±20 mA or 4–20 mA. Output modes are ±10 V or ±20 mA. Match the channel mode and program scaling to the field signal. See AS analog and measurement modules for additional channels.
AS228 transistor models support up to 6 axes of 200 kHz pulse output, and AS218 transistor models support up to 3 axes. The AS228R-A and AS218RX-A relay outputs have no built-in high-speed pulse function. Match the servo drive’s pulse input to the CPU output type.
Software, connection and expansion
Build the project in ISPSoft and set up the Mini USB data cable or RJ45 Ethernet connection in COMMGR. Check the AS PLC USB driver for USB or the PC and CPU IP settings for Ethernet. Delta PLC cable guide · Delta PLC software
The CPU provides Ethernet, two RS-485 ports, CANopen, Mini USB and a microSD slot. It supports Modbus TCP over Ethernet and Modbus RTU over RS-485. Delta lists system limits of 32 expansion modules and 1,024 physical I/O points in total. AS expansion modules · Digital I/O · Specialty modules · AS power supplies
Editor’s Note
Photograph the CPU nameplate first. The T, P or R in the model code identifies the output type.
On a used unit, check the removable terminals and ports. A missing terminal block can delay installation.
Back up the ISPSoft project, I/O layout and communication settings before removal.
Monitor the inputs online on the bench and check each output with a suitable test load.
On an AS218, check the analog channels in the selected signal range. Where the application uses pulse control, test the high-speed outputs separately.
Related topics
Delta AS300 · AS500 motion controllers · Delta PLC home · Used Delta products · Delta PLC and HMI manuals
Manufacturer references
AS228 installation sheet (includes EN) · AS218 installation sheet (includes EN) · AS hardware manual (EN) · AS series catalog (EN) · ISPSoft manual (EN)