Delta AS228P-A

Delta AS228P-A PLC with PNP transistor outputs

The Delta AS228P-A is a 24 V DC PLC CPU in the Delta AS200 family. It has 16 digital inputs, 12 PNP transistor outputs and a 64K-step program capacity. It can read sensors, run machine sequences and control 24 V DC field circuits in packaging and conveyor panels.

The AS228T-A has the same 16/12 I/O layout with NPN transistor outputs. The AS228R-A uses relay outputs. The AS218PX-A has PNP outputs, fewer digital points and built-in analog I/O. When selecting a replacement, compare the full model code, output type and existing field wiring.

Inputs, outputs and expansion

X0.0–X0.15 are rated at 24 V DC and a nominal 5 mA. Delta lists maximum input frequencies of 200 kHz for X0.0–X0.7 and 10 kHz for X0.8–X0.15. When connecting an encoder, check its signal type, the S/S common and the channel assignments for the selected counter mode.

The PNP outputs Y0.0–Y0.11 source positive voltage to the load when active. The resistive load ratings are 5–30 V DC, 0.5 A per output and 2 A per common. The outputs are grouped under C0, C1 and C2. When planning the panel, check the AS power supplies and the load budget for each output group.

All built-in I/O points are digital. See the AS expansion modules for additional channels, including digital I/O and analog measurement modules. Delta specifies up to 32 expansion modules and 1,024 physical I/O points with a supported module arrangement. Check the power budget against the planned hardware configuration.

ISPSoft, PC connection and communications

Use ISPSoft for programming. Connect the PC via a Mini USB data cable or Ethernet and select the corresponding channel in COMMGR. See Delta PLC cables for cable selection. The CPU also has two RS-485 ports, a CAN port and a microSD slot.

For CANopen setup, see CANopen Builder and CANopen cables. When integrating a DOP-100 HMI, check the panel driver against the PLC communication settings.

Editor’s Note

On the bench, start by checking the P-A suffix and the removable terminal blocks.
Before powering up, compare the CPU supply wiring and the C0, C1 and C2 commons with the wiring diagram.
Even when the output LED lights up, measure the signal with a suitable test load. Test at least one output from each common group.
If an encoder is fitted, check the count at low speed, the counting direction and whether the reading stays steady at rest.
If you can still access the old CPU, back up the available program, module order and communication settings before removing it.

PDFs and related topics

Delta PLC and HMI manuals · Delta PLC software · Delta PLC accessories