Delta AS500 motion controllers

Delta AS500 motion controllers

The Delta AS500 range combines PLC logic and servo motion control in one CPU within the Delta AS PLC family. It can coordinate feeding, positioning and cutting axes in packaging, labelling and printing machinery. Applications can use electronic gearing, electronic cams or interpolation. Start CPU selection with the installed servo system’s motion network and the required update time.

AS500 models

Delta AS516E-B · EtherCAT motion CPU. Delta specifies up to 16 real axes and a 1 ms update cycle for 16 axes with compatible EtherCAT servo drives.

Delta AS524C-B · CANopen DS402 motion CPU. Delta specifies up to 24 real axes and a 2 ms update cycle for four axes. Servo motion uses the CPU’s CAN1 Motion port.

Delta’s catalogue also lists the AS532EST-B and AS564EST-B. They support up to 32 and 64 real axes respectively when P2P axes are included. The same table lists limits of 4 and 8 for Motion axes.

Shared hardware and expansion

AS500 CPUs feature a 24 V DC supply, 20 MB of program memory, 20 MB of data memory, 16 digital inputs and 8 NPN outputs. They have two incremental encoder interfaces and one SSI absolute encoder interface. Check the encoder signal type and pinout against the CPU wiring diagram.

A supported configuration can accommodate up to 32 AS expansion modules, including up to 16 analog modules. Check AS power supply capacity when adding digital I/O and measurement modules.

Programming and drive selection

Select the exact CPU model in ISPSoft. AS500 CPUs support Ladder Diagram (LD) and Structured Text (ST). Set up the PC connection in COMMGR using a USB data cable or the standard Ethernet port. Check the CPU’s port labels before connecting Ethernet or EtherCAT.

Check the full model suffix and firmware on ASDA-A2 and ASDA-A3 drives. Use that model to select the device description file and servo manual for the motion network. On an existing machine, record the axis order and drive parameters before replacing the CPU.

Editor’s Note

When buying used, ask for the full CPU and drive nameplates. Use them to check the required motion network.

Count the real axes and the axes that must update in the same cycle separately.

On the bench, connect one compatible drive and check the axis status in software.

Compare the old project’s CPU model, firmware, axis order and encoder type with the installed hardware.

Before replacement, back up the PLC project, axis settings and drive parameters.

Related topics and manuals

Delta AS300 · Delta PLC category · Delta PLC and HMI manuals

Manufacturer documentation

Delta AS series catalogue (EN PDF) · Delta AS Motion CPU product page


Refine Search