Delta AS524C-B
Delta AS524C-B CANopen Motion Controller
Delta AS524C-B is an AS500 motion controller with PLC functionality that controls up to 24 physical servo axes over CANopen DS402. Physical, virtual and encoder axes share 32 axis addresses. The CPU has 16 digital inputs, 8 NPN transistor outputs, 20 MB of program memory and 20 MB of data memory. Applications include multi-axis positioning, electronic camming and synchronized cutting.
CAN1 Motion and CAN2 CANopen
CAN1 carries the servo motion network. Delta’s manual illustrates this connection with A2-M drives from the ASDA-A2 family. CAN2 handles standard CANopen DS301 traffic and can operate as a network master or slave. Select CANopen cables by port pinout and match each EDS file to the model and firmware of the device added to CAN2.
The AS516E-B in the Delta AS PLC family supports up to 16 physical axes over EtherCAT. The AS524C-B has two Ethernet ports plus RS-232 and RS-485. CAN1 has a built-in 120 Ω termination resistor.
Programming and hardware
Delta’s model-specific manual uses CANopen Builder. The controller supports LD and ST. Connect a PC over USB 2.0 or Ethernet. The Delta catalogue lists UC-PRG015-01A and UC-PRG030-01A as Mini USB PLC programming cables. When selecting from the Delta PLC software range, check the versions supported by the existing project and CPU firmware.
The CPU uses 24 V DC. Delta’s system example lists the AS-PS02 among the AS power supplies. The CPU provides two incremental encoder channels and one SSI absolute encoder channel. It supports up to 32 compatible right-side AS expansion modules, including up to 16 special modules such as analog and temperature modules. Check the address allocation and power budget for AS digital modules and AS analog measurement modules.
Editor’s Note
When buying used, confirm the AS524C-B label and look for the removable terminal blocks.
If the original CPU is available, save the project, firmware details and axis parameters first.
On a safe bench setup, confirm that the PLC goes online. Then test the inputs and NPN outputs one by one.
If a drive stays offline, check the CAN1 port, node address, bit rate and bus termination before replacing the CPU.
When replacing a CPU, compare encoder scaling, homing direction and I/O addresses. Test the first movement at low speed under safe conditions.
Related topics
Delta AS200 · Delta AS300 · AS04PU-A positioning module
Delta PLC and HMI manuals · Delta PLC category · Second-hand Delta products
External references
AS500C operation manual (EN) · Delta AS Series catalogue (EN) · AS524C-B instruction sheet (includes EN and TR)