Delta AS516E-B

Delta AS516E-B EtherCAT motion CPU

The Delta AS516E-B is a modular PLC CPU in the Delta AS500 motion controller range. It controls up to 16 real axes over EtherCAT. Typical applications include packaging, labelling and printing machines that synchronize feeding, positioning and cutting in the same machine cycle. Check the exact EtherCAT servo drive model and firmware when selecting a drive.

Power supply, I/O and expansion

The CPU requires a 24 V DC supply (±10%) and has 20 MB of program memory and 20 MB of data memory. It has 16 digital inputs and 8 NPN transistor outputs. Check the load connection and common terminal against the wiring diagram. The difference between NPN and PNP matters when replacing the CPU.

The CPU has two incremental encoder interfaces and one SSI absolute encoder interface. It sends servo axis commands over EtherCAT. The CPU takes up to 32 compatible local AS expansion modules, including up to 16 analog modules. Check the AS power supply capacity when adding digital modules.

EtherCAT and communications

Delta specifies a 1 ms update cycle for 16 axes and up to 32 axes when real and virtual axes are counted together. The catalogue’s motion network figures apply to Delta drives. Verify drive model and firmware support before specifying a third-party drive.

Interfaces include a dedicated EtherCAT motion port, Ethernet, USB, RS-232, RS-485 and CANopen DS301. The standard Ethernet port supports EtherNet/IP and Modbus TCP. The related Delta AS524C-B uses CANopen DS402 for motion. Compare the installed drive network and axis settings before selecting a replacement.

Programming software and PC connection

In Delta ISPSoft, select the AS5xx target for the AS516E-B. The CPU supports Ladder Diagram (LD) and Structured Text (ST). Configure the PC connection in COMMGR. For USB, check the Delta USB driver. For Ethernet, check the PC and CPU IP settings. Check the separate Ethernet and EtherCAT labels on the CPU. Where the project calls for them, match device description files to the installed drive model.

Editor’s Note

On a used unit, start by checking the full nameplate and the NPN output terminals.

On the bench, use a 24 V DC supply to check the CPU status LEDs and the ISPSoft connection.

Monitor an input in the software, then test an output separately with a suitable test load.

For the EtherCAT test, connect a compatible drive and check that you can read the axis status online.

Before removing a working CPU, back up the PLC project, axis settings and drive parameters.