Delta AS228T-A
Delta AS228T-A PLC CPU
The Delta AS228T-A is a compact AS200 PLC CPU with 16 digital inputs, 12 NPN transistor outputs, 64K program steps and a 24 V DC CPU supply. It suits packaging, labelling and sensor-driven machine control.
Supply and digital I/O
The CPU supply range is 20.4–28.8 V DC. See AS power supplies when sizing the panel supply for the CPU and expansion modules. Inputs X0.0–X0.15 are rated at 24 V DC, 5 mA. Use the wiring diagram to match the S/S common to the NPN or PNP field signal.
Outputs Y0.0–Y0.11 are NPN sinking outputs that switch load current toward 0 V. Delta specifies 5–30 V DC, 0.5 A per output and 2 A per common for resistive loads. Match the C0, C1 and C2 groups to the panel drawing.
High-speed counting and pulse outputs
The electrical input frequency limit is 200 kHz for X0.0–X0.7 and 10 kHz for X0.8–X0.15. Delta lists four high-speed counters and up to six pulse-controlled axes at 200 kHz. Check the counter mode, encoder A/B input pairs and pulse/direction assignment together.
Programming and communications
Open an existing project in ISPSoft. Use COMMGR for the PC connection over a Mini USB data cable or an RJ45 Ethernet cable. For USB, check the Delta driver and assigned COM port. See Delta PLC cables for cable selection.
The CPU provides Ethernet, two RS-485 ports, CANopen and a microSD slot. For a new DIADesigner project, check CPU and firmware support through Delta PLC software. See CANopen Builder for network configuration.
Model selection and expansion
The AS228P-A has the same I/O count with PNP outputs. The AS228R-A uses relay outputs. Consider the AS218TX-A for built-in analogue I/O or the AS320T-B for greater program capacity. Check input counts, commons and network ports when replacing the CPU.
For extra field points, see AS digital modules, including the AS16AM10N-A input and AS08AN01T-A NPN output modules. For measurement or an analogue command signal, see AS analogue modules, including the AS04AD-A input and AS04DA-A output modules.
Editor’s Note
For a used unit, check the full AS228T-A label and make sure both removable terminal blocks are present.
Check the 24 V DC bench supply first. Record the POWER, RUN and ERROR LED indications.
Before writing to the CPU, back up the readable program, hardware settings and network parameters.
With machine loads disconnected, test the inputs and all three output groups with a suitable test load.
If the project uses high-speed counting or pulse output, include the configured channel and frequency in the bench test.
PDFs and related topics
Start with our Delta PLC and HMI manuals. In Delta’s English hardware manual, Section 2.2 covers specifications and Section 4.6.8 shows the AS228T-A wiring diagram.
AS expansion modules · Delta AS PLC series · Delta PLC · Used Delta products
External references · Delta AS hardware and operation manual (EN) · AS228 installation sheet (TR/EN)