Delta EtherCAT cables
Delta EtherCAT Cables
Delta EtherCAT cables provide data connections between EtherCAT-capable controllers, servo drives and field devices. The UC-EMC series under Delta PLC accessories offers RJ45 assemblies in different lengths. The UC-EMC003-02A listed on this site is 0.3 m long.
The cable completes an existing EtherCAT interface; it does not independently add EtherCAT capability to a PLC or drive. Verify the complete device model, EtherCAT hardware, ports and installation requirements together.
UC-EMC models and lengths
The following mapping follows the EtherCAT cable table in the manufacturer’s 2024 AH catalogue. 02A and 02B are part of the complete order code. A dash means that the corresponding code is not listed in that table; do not invent an additional variant.
| Length | 02A | 02B |
|---|---|---|
| 0.3 m | UC-EMC003-02A | UC-EMC003-02B |
| 0.5 m | UC-EMC005-02A | UC-EMC005-02B |
| 1 m | UC-EMC010-02A | UC-EMC010-02B |
| 2 m | UC-EMC020-02A | UC-EMC020-02B |
| 3 m | — | UC-EMC030-02B |
| 5 m | UC-EMC050-02A | UC-EMC050-02B |
| 10 m | UC-EMC100-02A | UC-EMC100-02B |
| 20 m | UC-EMC200-02A | — |
The catalogue places the 02A group under ETG approved. Separately verify suitability for fixed installation or continuously moving cable carriers. Do not infer bending life, oil resistance or continuous-flex ratings from the suffix alone.
Controller and servo compatibility
The manufacturer’s connection guide shows AH10EMC-5A connections to EtherCAT drives. For Delta ASDA-A3 and Delta ASDA-B3, select the complete order code of the EtherCAT-equipped version. A shared drive-family name does not establish an identical communication interface.
Connect the controller or previous device to the IN port, and the next device to OUT. Check the actual port labels and topology against the device manual. Any added branching device must also suit the EtherCAT network design.
Cable class, shielding and distance
The ASDA-B3 EtherCAT wiring section specifies CAT5e STP cable and a maximum of 50 m between drives. This is a device-specific requirement, not a universal limit for every Delta product. Follow the more restrictive connection requirement of the controller and drive in use.
When selecting Delta industrial network cables, assess shield continuity, metal connector contact, strain relief and bending conditions. Avoid long parallel runs beside motor and power cables, and arrange cabinet wiring according to the equipment’s EMC instructions.
Distinguishing similar cables
CANopen cables may also use RJ45 connectors; this does not establish EtherCAT compatibility. Select DVP communication cables, DVP programming cables and network connectors for their respective functions. Do not substitute UC-EMC order codes with codes from another communication family.
Software, ESI files and commissioning
A passive cable does not receive a program or driver. An ESI file is the XML device description for an EtherCAT device, not for the cable. The configured device model and revision must match the connected hardware. Establishing the physical link and correctly configuring the device are separate checks.
Tools such as Delta ISPSoft and Delta COMMGR apply according to the controller family and task; their presence does not turn the cable into an EtherCAT programming adapter. Use the appropriate controller software to inspect network discovery, device order and operating states.
Editor's Note
Check the complete cable code and length first. Even between adjacent devices, leave enough slack to prevent strain on the connectors. Avoid folding spare cable into tight bends; selecting a suitable length helps prevent later intermittent faults.
For communication dropouts, compare the same two devices using a known-good, suitable cable. Change one item at a time and record the result. Replacing every cable while changing settings makes the original cause harder to identify.
Inspect broken RJ45 latches, loose metal shielding and crushed cable entries. If moving the cable interrupts communication, examine the connector, strain relief and equipment port separately. Do not force connectors while the equipment is energised.
A wire-map tester showing continuity is not a complete verification. Correct pair arrangement, shielding and errors during operation also matter. A cable that fails when moved can have damaged conductors beneath an apparently intact jacket.
Photograph and label IN/OUT connections before removal. When reconnecting, compare device order with the project. A drive appearing in the network scan does not establish correct cyclic data exchange or axis mapping; verify these separately.
If faults occur only while the motor runs, investigate shielding, grounding and proximity to power wiring. Supply dips, device settings and synchronisation faults can produce similar symptoms. Complete the final check under normal machine load.
PDF and software files
The document hub is Delta PLC accessories files. Further references are available through Delta PLC and HMI manuals and Delta user manuals. Sections 3.3–3.5 and Appendix A of the cable selection guide cover UC-EMC models and connections.