The Delta DVP28SV11T2 is a DVP-SV2 PLC CPU with 24 V DC power, 16 digital inputs and 12 NPN transistor outputs. It has 30,000 program steps and supports up to four axes of 200 kHz pulse output. It suits position control in labelling, packaging and cut-to-length machines.

Inputs, outputs and high-speed counting

The 24 V DC inputs are X0–X17 and the NPN outputs are Y0–Y13. When connecting PNP or NPN sensors, wire the S/S input common according to Delta’s diagram. The output commons are C0 (Y0–Y1), C1 (Y2–Y3), C2 (Y4–Y5), C3 (Y6–Y7) and C4 (Y10–Y13). An NPN output sinks the load current to 0 V. Check load power and the common terminals when wiring the control panel.

For high-speed counting, X0, X1, X4 and X5 are in the 200 kHz input group. Delta specifies 200 kHz operation for X10, X11, X14 and X15 on hardware versions later than A2. Check the CPU’s hardware label and the selected counter mode. When choosing an encoder, check the output type, signal level and assigned A/B input pair together.

Servo and stepper applications

Pulse terminals for the four motion axes are Y0, Y2, Y4 and Y6. Delta’s output table rates Y0–Y4 and Y6 at 200 kHz and Y5, Y7 and Y10–Y13 at 10 kHz. Follow the selected motion instruction’s diagram for pulse and direction wiring. Check that the servo drive or stepper drive accepts an NPN open-collector input signal.

On a packaging line, the PLC can read film travel from an encoder, verify a reference with an inductive sensor and move a servo motor by a set distance. On the first run, check direction, pulses per revolution and travel at low speed. For a stepper motor, microstepping affects the travel calculation. With a servo, check electronic gearing. Keep signal wiring away from power cables and follow the drive’s grounding diagram.

Programming software, cable and communications

Use WPLSoft or ISPSoft for PLC programming and select DVP-SV2 as the CPU family. In ISPSoft, set up the connection in COMMGR. The UC-PRG020-12A cable (2 m) connects to the CPU’s COM1 RS‑232 8-pin mini-DIN port. If the PC has no serial port, use a suitable USB-to-RS‑232 adapter with the UC-MS020-01A connection shown by Delta.

COM2 RS‑485 supports Modbus ASCII or Modbus RTU for industrial communications. Match the address, baud rate and parity when connecting an HMI or SCADA system. For Ethernet, consider the compatible left-side DVPEN01-SL module and Ethernet cabling. Check the mounting side when selecting DVP expansion modules.

Related models

The DVP28SV11R2 has relay outputs and the DVP28SV11S2 has PNP transistor outputs. The DVP24SV11T2 has 10 digital inputs, 12 NPN outputs and two analog inputs. The earlier DVP28SV11T is an SV series CPU with 16,000 program steps. Compare the label, output wiring and project CPU selection before replacing a unit.

Editor’s Note

When buying used, check the T2 suffix and hardware revision on the label.

Inspect the power connector, COM1 socket and output commons before energising the CPU.

Back up any readable program before making changes. Test the selected inputs with a known 24 V signal.

If the machine uses Y0, Y2, Y4 and Y6 for motion, check each pulse output with a test load and oscilloscope. The output LED gives no frequency reading.

For an encoder-based machine, use a short, low-speed move to compare direction with the count. This gives you more information about a used replacement than a RUN indication alone.

PDFs and technical documents

Related document index Delta DVP PLC files. The 16 March 2023 DVP-SV2 instruction sheet gives the input and output tables and NPN wiring. See the DVP-PLC Application Manual for instructions and Section 1.7 of the Delta PLC/HMI Cable Selection Guide for PC connections.

DVP28SV11T2 main page · DVP PLC series · Delta PLC accessories · Delta external terminals · Delta PLC · Used Delta models · Delta PLC and HMI manuals

Delta AS PLC · Delta AH PLC · Delta TP panels and remote I/O

External references

Delta DVP-SV2 Instruction Sheet (2023) · Delta DVP-PLC Application Manual (2020) · Delta PLC/HMI Cable Selection Guide (2019)