Delta DVP64EH00T — 32-input, 32-transistor-output PLC

The Delta DVP64EH00T is a 64-point PLC CPU from the original Delta DVP-EH series. It runs from a 100–240 V AC supply and has 32 digital 24 V DC inputs and 32 transistor outputs. Its 15,872-step program capacity and battery-backed SRAM suit existing conveyor, packaging and multi-station machines.

Input addresses and transistor outputs

The built-in PLC I/O uses octal addresses X0–X37 and Y0–Y37. For example, X10 follows X7. When connecting an inductive sensor, a photoelectric sensor or a limit switch, check the S/S input common against the field device’s PNP or NPN signal.

The CPU uses open-collector transistor outputs. Delta specifies 5–30 V DC for the output load circuit. Check the load supply and C0–C5 output commons against the terminal drawing. For a contactor or valve coil, select a suitable interposing relay and suppression device based on the coil voltage and current.

If a drive uses a high-speed pulse command, record the output address in the existing program and the drive’s required frequency. The original EH technical table gives its Y0/Y2 high-speed output note for the DVP20EH00T and DVP32EH00T. Before using a DVP64EH00T in a motion application, verify the channel and frequency for the specific hardware revision.

Programming software and cable

WPLSoft is the starting point for reading, backing up and monitoring an existing Ladder project on the original EH. Select the DVP-EH CPU and read a dated copy from the PLC before making program changes. If using ISPSoft, verify that the installed version offers the original EH CPU selection and can read from it. Set up the serial channel in COMMGR.

The PC connects through the CPU’s COM1 RS-232 port. Delta’s technical document lists the DVPACAB230 (3 m) and DVPACAB215 (1.5 m). On a computer without a serial port, use a suitable USB-to-RS-232 adapter and select the COM number assigned by its driver in WPLSoft.

COM2 and field communications

COM2 is an RS-485 port. For field communications with an HMI or variable frequency drive, compare the Modbus and RS-485 settings. Check whether the existing project uses Modbus RTU or Modbus ASCII. Save the station address, baud rate, parity and any SCADA register map with the project backup.

Related Delta models and expansion

The DVP64EH00R is the original-generation relay model with the same 32-input, 32-output count. The DVP64EH00T2 belongs to EH2 and the DVP64EH00T3 to EH3. Both have 32 inputs and 32 transistor outputs. When changing generations, check the PLC project, pulse instructions, output commons and expansion modules individually.

The original EH expansion table lists the DVP08HP11T digital I/O module and the DVP04AD-H analogue input module. Where the machine reads an analogue signal, record the channel type and program scaling as well as the module code.

Editor’s Note

Read the full label. When buying used, check the ordering code in a clear photo and identify the T, T2 or T3 suffix.

Check the BAT.LOW indicator. At the bench, read the program first. Save any machine recipes, retained D register values and HMI settings.

Test the outputs under load. With machine loads disconnected, check each output group with a suitable low-voltage DC test load.

Test the last group too. Inspect X30–X37 and Y30–Y37 for worn or loose terminals. Compare the monitored state with what happens at the terminal.

Test both serial ports separately. Read the program through COM1 and check for a response from the field device on COM2. Inspect the terminals and protective grounding before applying power.

Internal references and PDF files

Delta DVP PLC PDF files · Hardware documentation, programming guides and catalogues.

Original DVP-EH series · Delta PLC models · Used Delta equipment

External references

Delta DVP-EH hardware and wiring sheet · Original 64EH terminal layout, supply and serial ports.

Delta DVP PLC technical information · Exact model on PDF page 20, EH memory table on page 14, and WPLSoft and cables on page 22.