6ES5 988-3NB41

Siemens 6ES5 988-3NB41 — fan replacement package for 955 power supplies

Siemens 6ES5 988-3NB41 is a fan replacement package for selected 955 power supplies in Siemens S5 systems. The manufacturer data sheet identifies the families as 6ES5 955-3LC4X, -3LF4X, -3NC4X and -3NF4X. In SIMATIC S5 maintenance, it belongs to the power-supply cooling assembly.

Its purpose is to help maintain cooling airflow around the power supply. Selection requires the complete PSU number, manufacturer type and existing fan connections, as well as a visual comparison.

Compatible 955 power-supply families

The 3LC4X family includes 6ES5 955-3LC41 and 6ES5 955-3LC42; 3LF4X examples include 6ES5 955-3LF41 and 6ES5 955-3LF42. X denotes the variable final character in the family description. Record the actual final digit from the installed unit.

3NC4X examples include 6ES5 955-3NC41 and 6ES5 955-3NC42; 3NF4X includes 6ES5 955-3NF41 and 6ES5 955-3NF42. Do not use the PSU input-voltage rating as the fan motor’s operating-voltage specification.

The S5-135U/155U spare-parts table lists 988-3NB41 for the WKF RZF power-supply type and distinguishes other manufacturer types. Check that identification in addition to the 955 order number.

Fan subassembly and delivery scope

Siemens describes the part as a fan subassembly with fan and rechargeable-battery terminals. Three separate fans in the relevant PSU do not establish that one replacement package contains three fans or a battery. Verify the actual delivery scope and assembly completeness from clear photographs.

The right-hand fan subassembly includes the rechargeable-battery location, so replacement there also concerns the battery and its connections. Record the original location, wiring and retainers before removal. Follow the installed PSU’s maintenance procedure for battery work.

Air path, filter and fan monitoring

Inspect air inlets and any installed 6ES5 981-0FA41 filter assembly alongside the fan. Siemens explains that a clogged filter can cause the Alarm indicator to light and Fan 1/2/3 indicators to flash together. Check the filter and air path before interpreting this as three failed fans.

In the S5 rack layout, keep cables and foreign objects clear of the lower air inlet. Rotation alone does not establish adequate cooling. Assess airflow direction, the air path, installation and PSU monitoring indications together.

Distinguishing related part numbers

The 6ES5 988-3LA11 and 6ES5 988-3NA11 are different fan products. Similar housings or connectors do not establish interchangeability with the 988-3NB41. Check each item’s application and supply requirements.

The 6ES5 988-7NA11 is also a separate replacement package. When examining assemblies such as 6ES5 981-0HA11 and 6ES5 981-0HA21, record the main assembly separately from its spare-fan number. Select using complete numbers and documented matching, rather than the shared 988 prefix.

Checks after replacement

During system troubleshooting, record startup, noise, vibration and return to normal operation separately. Check the relevant PSU’s fan and alarm indications. Resetting an alarm does not repair a blocked filter or defective fan.

Confirm the PLC program backup and existing backup arrangements when planning maintenance. Select the replacement procedure from the installed PSU documentation. Do not disable monitoring or protection connections simply to suppress a fan indication.

Editor’s note

When buying a used Siemens fan assembly, check its 988-3NB41 label and the intended PSU label. Include the WKF RZF type identification in that comparison. Similar-looking parts need not belong to the same assembly.

Free rotation by hand is only an initial mechanical check. With power disconnected, inspect blade damage, rubbing and bearing play. In the correct operating arrangement, check reliable startup, noise and vibration as well.

Do not infer fan voltage from the PSU mains label. Establish the motor rating, connections and manufacturer arrangement before testing. An unsuitable connector is not a reason to begin by cutting and splicing wires.

If all fan indicators report a problem, inspect the inlet and filter too. Installing a replacement fan while retaining a blocked filter leaves the cooling problem unresolved. Recheck indications and the air path after cleaning.

Treat battery connections in the right-hand assembly separately from ordinary fan wiring. Photograph the original arrangement and record polarity. Do not assume that a battery is included in the package.

For legacy S5 systems, a useful test record identifies the PSU, fan position and final alarm condition. Preserve the program backup and photographs taken before removal alongside that record.

OtomasyonAVM resources and PDFs

+ Siemens S5 PDF archive: system and PSU documentation. The manufacturer’s S5-135U/155U manual is linked below.

+ 6ES5 988-3NB41 model page and used Siemens S5 models: the fan package and related system parts.

Related topics

+ 6ES5 955-3LC41 · 6ES5 955-3LF41 · 6ES5 955-3NC41 · 6ES5 955-3NF41: PSU examples within the specified families.

+ 6ES5 981-0FA41 filter assembly and 6ES5 988-7NA11 fan package: distinguish different maintenance-part numbers.

Browse SIMATIC S5

Siemens S5 · S5 power supplies · S5 expansion products · Second-hand Siemens products

Siemens and external references

+ Siemens 6ES5988-3NB41 data sheet — manufacturer document hosted by ALL4SPS. Specifies the 955-3LC4X/-3LF4X/-3NC4X/-3NF4X families.

+ Siemens S5-135U/155U System Manual — 6ES5 998-0SH21, Edition 07, English. Siemens manufacturer document hosted by SPS-Service. Section 4.3.4: fan, battery and filter maintenance; Appendix A, page A-3: 988-3NB41 and WKF RZF matching.

+ Siemens ST 50 — SIMATIC S5 catalog, English. Fan assemblies, replacement fans and PSU spare parts.