6ES5 981-0HA11
Siemens 6ES5 981-0HA11 SIMATIC S5 long-rack fan assembly
The 6ES5 981-0HA11 is a 115/230 V AC cooling assembly mounted below long racks in SIMATIC S5-115 systems. It has two fans, a dust filter and a fan-fault contact. The 6ES5 981-0HA21 fits the same long-rack format and takes a 24 V DC supply. Read the full part number and supply rating from the fan assembly’s own nameplate before ordering a spare.
Technical specifications
Supply 115/230 V AC (±10%), 50/60 Hz. Typical input current 420 mA. Dimensions 423 × 110 × 135 mm (W × H × D). Weight 1.5 kg. Protection IP20.
The S5-115U manual specifies forced cooling when the PS 951-7LD21, 7LD51 or PS 951-7ND41 carries more than 7 A, or when the rack contains high-consumption modules. Check the S5 power supply part number and the load of any communications modules when assessing the rack’s cooling needs.
Rack fit and mounting hardware
Start with the rack label. Compare the central rack references 6ES5 700-1LA12, 6ES5 700-2LA12 and 6ES5 700-2LA22. For narrower racks such as the 6ES5 700-0LB11, check the mounting dimensions of the 294 mm 0HB11 variant.
For an expansion rack, check the actual 6ES5 701-1LA12, 6ES5 701-2LA12 or 6ES5 701-3LA13 label, cabinet clearance and mounting points.
Siemens lists the 6ES5 981-0JA11 filter unit and the 6ES5 981-0GA11 mounting kit, which consists of two brackets and a cable duct. The brackets support the fan below the rack. Keep the airflow path and filter accessible when routing S5 cables and connectors and wiring to the expansion interface modules.
Fault contact and service checks
Terminals 1, 2 and 3 are the voltage-free changeover contact. During normal operation, 1–2 is closed and 1–3 is open. A fan fault opens 1–2 and closes 1–3. If the alarm is wired to an S5 digital input, check the input supply and the machine’s alarm logic against the cabinet drawing.
Qualified service personnel can use Figure 3-36 of the Siemens S5-115H manual to cross-check the supply and selector setting against the device label. The AC drawing shows a 600 mA time-delay fuse. Check the fuse type, cabinet mounting hardware and filter individually during inspection.
The 6ES5 988-7NA11 replacement kit contains one fan motor, a connector and repair instructions. See the SIMATIC S5 PLC overview for the rack’s place in the system.
For a used unit, ask qualified staff to check that both fans start smoothly, deliver airflow and trigger the expected fault-contact change during a bench test. Request a nameplate photo and confirm whether the filter and 0GA11 brackets are included.
If you have a unit to sell, send the full part number, quantity, condition, nameplate photo and asking price to otomasyonavm@gmail.com.
Siemens PDF documentation
The 6ES5 981-0HA11 data sheet (EN) identifies the part and supply. The S5-115U system manual (EN) lists specifications on p. 15-67 and fan maintenance in Appendix B. The S5-115H system manual (EN) shows the wiring and fault contact in Figure 3-36. OtomasyonAVM Siemens S5-115 PDF archive.
Related topics
24 V DC long-rack fan assembly · Long-rack fan mounting kit · SIMATIC S5 fan motor replacement kit
Second-hand Siemens navigation
SIMATIC S5 racks and fan assemblies · SIMATIC S5 CPU families · Siemens SIMATIC S5 · Second-hand Siemens