6ES5 981-0FA41
Siemens 6ES5 981-0FA41 – SIMATIC S5 Dust Filter Holder Assembly
Siemens 6ES5 981-0FA41 is a dust filter holder assembly used in the cooling arrangement of SIMATIC S5 central and expansion racks. Associated with the ZG 188U, EG 183U and EG 185U families, this mechanical accessory holds the filter mat in the air inlet. Within Siemens S5 PLC systems, it belongs among auxiliary equipment and power supply accessories.
The Siemens S5-135U/155U ordering table lists the holder, guides and 10 filter mats, with the designation WKF RZF. Replacement mats have the separate order number 6ES5 981-0EA41. In the S5 system, the holder has a mechanical role and requires neither an electrical supply nor a PLC address.
Rack and power supply compatibility
Do not select the assembly from the 188U, 183U or 185U family name alone. Check the complete rack label: 6ES5 188-3UA11, 6ES5 183-3UA12 and 6ES5 185-3UA11 are different rack examples within these families. Other suffixes, such as 6ES5 188-3UA12 or 6ES5 183-3UA22, require inspection of the installed supply and fan arrangement.
Record power supply codes such as 6ES5 955-3LC41, 6ES5 955-3LF41, 6ES5 955-3NC41 and 6ES5 955-3NF41. The drawer mounting points, guides and latch must match the actual housing. Neither the rack family nor its voltage rating establishes mechanical compatibility; the supplies listed here are not an unconditional fit guarantee for every installation.
Installation position and construction
The manual places the filter drawer underneath the power supply housing. The arrangement comprises two plug-in guides, the drawer, a filter mat and a retaining grid. Leave clearance beneath the power supply for drawer removal and ensure that cables and connections do not obstruct its movement.
Installation sequence: seat the guides' round tabs in the housing openings, insert the mat and secure it with the grid, then slide the drawer into the guides, push it back and swivel it upward until it latches. If the housing lacks the required mounting points, do not force the holder into place or drill it to obtain a fit.
Check the holder, mat and fan separately
0FA41 identifies the holder assembly; 0EA41 identifies the replacement mats. The fan unit is a separate component. A sound holder does not establish that the mat is clean or the fan works. For used equipment, verify through photographs whether the guides, retaining grid and mats are included.
Gaps around the mat can allow unfiltered air through, while an unsuitable or excessively restrictive mat can reduce airflow. Preserve the correct material and seating arrangement. Adding thicker foam does not establish better cooling.
Maintenance and troubleshooting
Siemens makes the mat replacement interval dependent on operating environmental conditions. Consider dust loading, oily contamination and operating hours when planning maintenance. In the relevant power supply arrangement, the manual associates a clogged mat with inadequate airflow, an Alarm indication and fan warnings. These indications belong to the power supply monitoring system, not the holder itself.
During troubleshooting, check the mat, fan operation and clear airflow path together. When investigating a CPU problem that appears as the installation heats up, recording cooling conditions helps support a better replacement decision.
Editor's note
Start with the latch and guides. A drawer that slides into place but does not latch has not passed a useful inspection; vibration may allow it to open.
A front photograph alone is insufficient. Inspect the side guides, retaining grid and mounting tabs. A small missing part can leave an otherwise usable assembly incomplete.
Check for oil and dust embedded inside the old mat even when its surface looks clean. Use an appropriate replacement rather than restricting the inlet with a random piece of thick foam.
Inspect the surrounding housing after removing the filter. Avoid blowing accumulated dirt onto electronic boards; remove it using a controlled cleaning method.
After maintenance, check more than whether the drawer is closed. Verify latching, fan operation and the airflow path, and establish that any warning's actual cause has been addressed.
When buying used Siemens equipment, a power supply or a PLC rack supply, include the filter assembly in the delivery record. The catalogue's ten-mat package description does not establish that a used item includes ten clean mats.
OtomasyonAVM resources and manual
Browse About Siemens S5 PLC, S5 auxiliary equipment and power supply accessories for related components. Installation and ordering details for this holder are described in the S5-135U/155U system manual linked below.
Related equipment
+ 6ES5 188-3UA11: central rack example; inspect the installed cooling arrangement.
+ 6ES5 183-3UA12: EG 183U expansion unit.
+ 6ES5 185-3UA11: EG 185U expansion unit.
+ 6ES5 955-3LC41: power supply example in the related rack family.
Browse S5 equipment
Siemens S5 PLC · CPU family · Auxiliary equipment · Cables · Supply accessories · Used Siemens equipment
Manufacturer documents and external references
+ Siemens S5-135U/155U System Manual – C79000-G8576-C199-07, English: printed page 4-34 / PDF page 100 covers drawer installation; 4-46 / PDF page 112 covers mat replacement; A-3 / PDF page 551 lists the 981-0FA41 and 981-0EA41 ordering scope.
+ Siemens ST 50, 1998 – S5-135U and S5-155U/H catalogue: archive copy of the manufacturer's catalogue. Printed page 4/156 lists filter holders and separate replacement mats.