6ES5 955-3LC42

Siemens 6ES5 955-3LC42 — S5-135U/155U 18 A Power Supply

The Siemens 6ES5 955-3LC42 is a fan-cooled SIMATIC S5 PS 955 power supply for the S5-135U/155U central controller and specified 183U/185U expansion units. A front-panel switch selects 120 or 230 V AC. The main output is 5.1 V DC at 18 A, with auxiliary outputs of 15 V DC at 0.5 A and 24 V DC at 1 A.

The unit powers the modules through the backplane and provides airflow through the S5 rack. Siemens lists it for the 6ES5 188-3UA12 central controller and the 6ES5 183-3UA13 and 6ES5 185-3UA13 expansion units.

120 V and 230 V input settings

The 120 V setting accepts 93–132 V AC, and the 230 V setting accepts 187–264 V AC. The nominal frequency is 50/60 Hz, with a permissible range of 47–63 Hz. Isolate the incoming mains before adjusting the voltage selector. The front-panel Power switch controls standby.

Backplane outputs and field supplies

The 5 V and 15 V rails are regulated. The 24 V output has a combined 1 A limit across X2 and the front terminals. Use the cabinet drawings to trace the field supplies for digital input, digital output and analog modules. Use the rack wiring diagram for interface modules and other backplane loads.

The Voltage low LED lights when the field load voltage at the Voltage Monitor input drops below 14 V. The 5V o.k., 15V o.k. and 24V o.k. LEDs indicate the status of the power supply outputs. At the 5 V current test socket, 3 V corresponds to 18 A. Trace power wiring separately from the S5 signal and interconnect cables to identify the right test point.

Comparing similar 955 order numbers

The 6ES5 955-3LF42 also takes 120/230 V AC and is listed with a 40 A main output for the 6ES5 188-3UA22 central controller. The 6ES5 955-3NC42 retains the 18 A main output, takes 24 V DC and is listed for the 6ES5 188-3UA32. The 6ES5 955-3NF42 is the 24 V DC input, 40 A version.

Check the 6ES5 955-3LC41 and 6ES5 955-3LC14 separately when comparing close order numbers. The 6ES5 955-3NA12 is a different 135U unit with a 24 V DC input and a 10 A main output. Match both the rack label and the full power supply order number when selecting a spare.

Editor’s note

Read the label and selector together. Confirm the 3LC42 suffix, then check that the 120/230 V setting matches the cabinet supply before energising the rack.

Record the LEDs before resetting a fault. If Voltage low appears while the output LEDs stay on, start with the external load supply and its monitor wiring. The Siemens S5 PLC overview identifies the main rack and module groups.

Check the airflow when the fans raise an alarm. Siemens associates all three fan LEDs flashing together with Alarm lit with inadequate airflow. Check the filter if fitted and look for obstructions at the inlet and outlet.

Distinguish the battery warnings. MB low refers to the main battery circuit and RB low to the rechargeable reserve battery. Before planning removal, confirm you have a program backup on the S5 memory card or programming device.

Ask for a loaded test when buying used. For used PLC power supplies, check the label, fan operation and readings from all three outputs. Siemens specifies a 0.5 A minimum load on the 5 V rail.

OtomasyonAVM resources and PDFs

Siemens S5 PLC overview · 6ES5 188-3UA12 central controller · 6ES5 183-3UA13 expansion unit

SIMATIC S5 manuals and PDF archive. See the S5-135U/155U system manual below for this model’s specifications.

Related topics

3LF42 — 120/230 V AC input, 5 V at 40 A output · 3NC42 — 24 V DC input, 5 V at 18 A output

Browse SIMATIC S5

SIMATIC S5 range · Siemens S5 PLCs and modules

External references

Siemens 6ES5 955-3LC42 product record · S5-135U/155U system manual — rack compatibility, p. 4-19

Input and output specifications, pp. 4-51–4-53 · LEDs and fault diagnostics, p. 4-36 · Siemens power supply jumper settings