6ES5 955-3NC42

Siemens 6ES5 955-3NC42 SIMATIC S5-135U/155U Power Supply

The Siemens 6ES5 955-3NC42 is a fan-cooled SIMATIC S5 power supply for the S5-135U/155U central controller and specific EU 183/185 expansion units. It takes a 24 V DC input and delivers 5.1 V DC at 18 A on the main rail, plus 15 V DC at 0.5 A and 24 V DC at 1 A on the auxiliary rails. Its input range, including ripple, is 19.2–33 V DC.

In a machine cabinet, the 3NC42 powers the SIMATIC S5 rack modules and uses three fans to move cooling air through the rack. The similar-looking 6ES5 955-3NF42 also runs on 24 V DC and supplies 40 A on the main rail. The 6ES5 955-3LC42 is an 18 A unit with a 120/230 V AC input.

Which racks take the 3NC42?

Siemens lists the 3NC42 with the 6ES5 188-3UA32 central controller, the 6ES5 183-3UA22 expansion unit and the 6ES5 185-3UA23 expansion unit. A cabinet may contain a central rack and several S5 expansion units. Identify the rack that lost power and read its full order number before selecting a spare.

The S5-135U/155U family includes different processors, such as the CPU 947 and CPU 948. Match the supply to the order number of the S5 rack and the label on the installed power supply.

What do the input and output current ratings mean?

At 24 V DC and rated load, the unit draws 9.5 A at its input. The 18 A rating belongs to the 5.1 V output, which requires a 0.5 A minimum load. On the 24 V auxiliary output, X2 and the front terminals share a 1 A limit. When tracing field power for S5 digital input modules and digital output modules, use the cabinet drawing to identify the loads connected to that rail.

The DC-fed 6ES5 955-3NA12 is rated at 10 A on its main output, while the AC-fed 6ES5 955-3LF42 is a 40 A unit. Compare the input supply, the rating of each output and the rack assignment when sourcing a replacement.

What do the fan, voltage and battery indicators show?

The green 5V o.k., 15V o.k. and 24V o.k. LEDs indicate the state of the respective rails. Each of the three fans has its own indicator. If one fails, the remaining two can speed up. The F–R jumper determines whether the supply shuts down after two fan failures or inadequate airflow. If S5 interface modules also report faults during an outage, note the sequence and check the supply in the affected rack.

MB low flags the main backup battery and RB low flags the rechargeable battery. In the central controller and EU 185, a lithium or external battery can retain data when system power is off. Before service, identify the S5 memory card in use and confirm that the program backup is available.

Editor’s note

Photograph both labels. Keep the rack order number and the 3NC42 suffix in the same service record. 3NC41 and 7NC12 are distinct order numbers. For a used spare, read the complete number in the seller’s label photo.

Check the input under load. If the fault occurs at machine start-up, look for a drop on the 24 V feed at that moment. Have the EN enable circuit and the S5 cables and connectors checked against the cabinet drawing.

Check airflow when a fan warning appears. Record the fan LED and the state of the Fan Warning and Fan Alarm relays. Check the filter and airflow, then compare the F–R setting with the Siemens table.

Record the settings before removal. Follow the site’s isolation procedure and document terminal markings and accessible jumper positions. Include program backup and battery status in the service plan. Once the Siemens S5 PLC is back in service, check the power supply and CPU indications separately.

Ask for a load test on used units. The record should show the 5.1 V, 15 V and 24 V rails, the loads applied, all three fans running and any battery warnings. Use the S5 maintenance overview alongside the test requirements for the actual rack.

OtomasyonAVM resources and PDFs

See the 6ES5 188-3UA32 central controller page for the rack reference and the 6ES5 183-3UA22 page to identify the expansion unit.

Browse the OtomasyonAVM S5 PDF archive. Our Siemens S5 PLC overview and system manuals page also links to the S5-135U/155U system manual.

Related topics

Compare the 3LC42, the 18 A AC-input unit and the 3NF42, the 40 A DC-input unit.

S5 navigation

Siemens S5 PLC · SIMATIC S5 · S5 power supplies

External references

Siemens SIMATIC S5-135U/155U system manual (English PDF). See section 4.3, especially printed pages 4-19, 4-38 and 4-54–4-56.

Siemens S5-135U/155U power supply jumper settings, C79000-Z8574-C198-01 (German/English PDF). Covers four variants, including the 3NC42.