Delta UC-PRG015-02A

Delta UC-PRG015-02A

Delta UC-PRG015-02A is a 1.5 m USB Type-A male ↔ USB Type-B male cable used between a computer and the USB Type-B programming port of a suitable Delta TP panel or HMI. Delta catalogues list it for TP-to-PC connections, and the cable selection guide also shows it for suitable USB Type-B ports on DOP devices. It supports project transfer and the communication functions permitted by the connected device and its software.

This model is not a mini USB cable, Ethernet cable or USB-to-RS-232 converter. It carries the USB data connection; device recognition, drivers and programming methods depend on the connected panel. When comparing models in the Delta DVP programming cables group, check the connector, complete panel model and port function together.

Length and USB connection arrangement

Model: UC-PRG015-02A. Length: 1.5 m. Computer end: USB Type-A male. Device end: four-contact USB Type-B male. Type-B differs from mini USB and micro USB. A panel's USB host port and its USB device port for computer programming serve different purposes.

Figure 19 in Delta's cable guide shows 1 ↔ 1: +5 V / red, 2 ↔ 2: D− / white, 3 ↔ 3: D+ / green and 4 ↔ 4: GND / black. Observe the connector viewing orientation when identifying pins. The USB +5 V connection does not establish that it can replace the external operating supply specified on the panel's label.

TP04P, TP70P and DOP connections

The manufacturer's cable guide lists UC-PRG015-02A for USB Type-B connections on the TP04P and TP70P groups. Documented examples include TP04P-16TP1R and TP70P-22XA1R. Do not assume that every device under Delta TP panels and remote I/O uses the same programming connection.

For HMI series such as DOP-B and DOP-W, follow the manual for the complete model equipped with a USB Type-B port. A matching socket alone does not establish identical project software, USB drivers or supported transfer operations.

USB drivers and virtual COM ports

A USB-to-serial converter inside a cable and a virtual COM port provided by a panel are different arrangements. The TP70P manual explains that installing the panel's USB driver creates a communication port under Ports (COM & LPT) in Windows Device Manager. A COM number can therefore appear with this connection; it is provided through the connected panel's USB interface and driver.

In the TP70P example, TPEditor transfers the panel project, while WPLSoft transfers and monitors the PLC program. Select the correct device model and detected port in the software. For DOP HMIs, check the model's supported DOPSoft version and USB communication method. No firmware or program is installed in the cable, although an operating-system-compatible device driver may be required.

Differences from similar UC-PRG cables

UC-PRG030-02A is the 3 m option for the same USB Type-A-to-Type-B connection duty. UC-PRG015-01A and UC-PRG030-01A use mini USB. UC-PRG030-10A provides a DB9 serial connection, and UC-PRG030-20A provides RJ45 Ethernet. UC-PRG020-12A belongs to the USB/serial connection group. 015-02A and 015-01A have different device-end connectors.

Editor's Note

When ordering, provide the complete panel code and a photograph of its socket as well as the cable name. Confusing Type-B with mini USB can leave you with a perfectly good cable that will not fit.

If the computer cannot detect the panel, start with a direct connection to a known-good USB port. Reduce extension leads and hubs during the initial check. Inspect crushed plug entries and loose sockets for intermittent contact.

For TP70P connections, check Device Manager for an unrecognised device or missing driver. Do not blame every USB failure on the cable; the correct panel driver may be needed before TPEditor can find its port.

If the panel does not start, do not treat the USB cable as its power supply. Check the device's operating supply, fuse and terminals against its label ratings. Assess communication and power faults separately.

Do not force a plug into position if the panel's Type-B socket has loosened from its board. Testing a known-good cable with another suitable device helps separate cable faults from socket damage. Never apply external 24 V to the USB wiring.

Once connected, back up the panel project and PLC program separately before sending a new project. Successfully reading one does not prove the other has been backed up. Verify the model and transfer direction before proceeding.

PDF documents, USB connections and software

Use our Delta PLC accessories PDF and software files page for cable and driver documentation. Panel documents are available under Delta TP panel files, with general documents under Delta PLC and HMI manuals. The USB pin arrangement appears in Figure 19 of the Delta PLC/HMI Cable Selection Guide and in the cable appendix of the DVP training kit manual.

Related subjects

Delta TP04P · TP04P-16TP1R · Delta TP70P · TP70P-22XA1R · TP panels and remote I/O · DOP-B HMI · DOP-W HMI · TPEditor · WPLSoft

UC-PRG030-02A · UC-PRG015-01A · UC-PRG030-01A · UC-PRG030-10A · UC-PRG030-20A · UC-PRG020-12A · DVP communication cables

Navigation: Delta DVP programming cables · Delta PLC accessories · Delta DVP PLC series · Delta PLC models · Used Delta products · PDF and software files

External references

Delta PLC/HMI Cable Selection Guide – TP/DOP connections and Figure 19 · Delta DVP/TP catalogue – UC-PRG015-02A accessory information · Delta DVP starter kit manual – USB cable pin assignments · Delta TP70P Quick Start – USB driver, TPEditor and WPLSoft