Delta DVP32XP200T
Delta DVP32XP200T is a 32-point mixed digital I/O expansion module with 16 inputs and 16 NPN sinking transistor outputs, listed in the DVP-ES2 / EX2 expansion family. Its main supply is 100–240 V AC. It connects to a compatible host PLC through the expansion interface and relies on the host PLC CPU to execute the program and process its PLC I/O.
Typical duties include collecting signals from sensors, pushbuttons and limit switches, and switching suitable DC loads. For DVP-ES2 and DVP-EX2 systems, check the exact host model, permitted expansion count and power budget. For another generation such as DVP-ES3, follow the relevant CPU manual; the shared DVP name alone does not establish compatibility.
Specifications and separate power circuits
Inputs: 16 channels, 24 V DC, approximately 5 mA/channel and 4.7 kΩ input impedance. ON level is >15 V DC and OFF level is <5 V DC. The installation sheet specifies 10 ms ±10% OFF-to-ON and 15 ms ±10% ON-to-OFF response. The S/S common supports sink/source input wiring.
Outputs: 16 NPN sinking transistor channels for 5–30 V DC loads. They are transistor outputs, so AC loads require a suitable interface. The sheet lists 50 µs ON response, 200 µs OFF response and a maximum switching frequency of 1 kHz, subject to the CPU scan. These figures do not make this a dedicated high-speed pulse or motion module.
Conflicting current ratings: the selection table in DVP Series Module Manual (printed 1-2, PDF page 18) lists 0.5 A/output and 4 A/common, while the exact-model wiring section 2.5.16 (printed 2-19, PDF page 53) lists 0.3 A/output and 1.2 A/common. The general transistor table in the 21 February 2024 installation sheet also gives 0.5 A and 4 A. The documents do not identify which hardware revision explains the difference. Obtain manufacturer confirmation for the actual unit before using the higher values as design limits.
Main supply: 100–240 V AC, 50/60 Hz at L/N; the sheet lists −15%/+10% voltage tolerance and 20 VA consumption for the T version. The +24V/24G auxiliary output is rated 100 mA. The transistor stage requires external 24 V DC (−15%/+20%) at UP and ZP. The manual’s maximum 30 mA electronic consumption excludes field-load current. Include sensors and output loads separately when sizing the power supply.
Installation: 35 mm DIN rail or M4 screws; operating temperature 0–55 °C. Drawing dimensions are L=145 mm width, L1=137 mm mounting-hole spacing and 78 mm depth. Body height is 90 mm, increasing to 110 mm including mounting projections. Allow terminal and wiring clearance when arranging panel components.
S/S, UP and ZP wiring
For PNP/NPN sensors, connect S/S to 0 V for PNP operation or to +24 V for NPN operation. Check the sink/source circuit against the actual sensor output. With inductive sensors, capacitive sensors and photoelectric sensors, both polarity and common reference matter. Do not apply encoder pulses faster than these standard inputs can capture.
UP is the positive output-stage supply connection. ZP0 is the 0 V common for Y0–Y7; ZP1 serves Y10–Y17. With NPN outputs, the other side of each load connects to positive supply. Do not directly parallel the +24V/24G auxiliary output with an external supply. Use an appropriate DIN rail power supply and fuses for the load branches. Add suitable suppression to DC coils and assess the operating and pull-in current of contactors and interface relays.
Addressing, software and programming cable
X0–X17 and Y0–Y17 printed on the module are local terminal labels. As the first and only digital expansion after a DVP32ES200R/T CPU with 16 built-in inputs and 16 outputs, the module occupies X20–X37 and Y20–Y37. Addressing is octal: X30 follows X27. A different host or preceding expansion changes the starting addresses; check the actual I/O map before commissioning.
No separate program is downloaded to DVP32XP200T. Develop the host CPU application using WPLSoft or ISPSoft where the CPU and version support it. Check COMMGR settings for an ISPSoft connection. Basic module operation uses X/Y addresses without analog channel-range configuration. The host handles PLC operation and the automation sequence.
Connect the programming cable to the CPU. The catalogue lists UC-PRG020-12A, a 2 m DB9 female to 8-pin mini-DIN male cable, for suitable DVP RS-232 ports. A PC without a serial port needs a suitable USB–RS-232 adapter, its driver and the correct COM settings. Match the PLC cable pinout to the actual host port. This expansion has no independent USB/Ethernet programming port. HMI and SCADA connections use an appropriate communication port on the host.
Related models and topics
DVP32XP200R provides the same 16-input/16-output distribution with relay outputs. DVP24XP200R and DVP24XP200T offer 16 inputs/8 outputs; DVP24XN200R and DVP24XN200T serve 24-output requirements. Different output circuits or point counts prevent treating these as automatic replacements.
Smaller expansion options: Delta DVP08XM211N · Delta DVP08XN211R · Delta DVP08XN211T · Delta DVP08XP211R · Delta DVP08XP211T. For analog signals, consider the separate DVP04AD-E2 and DVP04DA-E2 module class. The digital outputs here do not directly generate an analog speed reference for an AC drive.
Editor’s Note
Read the complete 200T suffix first. Before replacing an older XP11T unit, compare the supply, expansion generation and output wiring, even when the housings look similar.
A lit Power indicator does not establish that the output stage works. Measure the 24 V at UP and both ZP commons under load; a failed group may also be caused by its common wiring or terminal contact.
Disconnect machine loads for the initial bench check and test each channel with a small current-limited load. If the Y indicator and measured load state disagree, check wiring before the output stage. A bench test does not resolve the documented current-rating conflict.
If an input indicator responds but the program does not, check the shifted addresses. A wrong S/S connection can make an entire sensor group appear faulty. Trace the commons and relay operation one circuit at a time.
On a repaired board, inspect coil suppression, load current, soldering and common tracks as well as the replacement transistor. Isolate a unit with a burned or carbonised mains section; insulation checks are needed after repair.
For a used unit, request label and terminal photographs, an online test with the host CPU and a record covering every input and output. The model code alone does not establish stock condition or a passed test.
PDF manuals and technical documents
Start with the Delta DVP PLC files page. The model record includes DVP-ES2 DIDO installation instructions (DVP-0131130-01, 21 February 2024, 19 pages; English/Chinese) and DVP Series Module Manual (5th edition dated 6 January 2026, DVP-0399820-05, 913 pages; English). Use the exact DVP32XP200T wiring section.