Delta DVP16EH00R2

Delta DVP16EH00R2 – EH2 PLC with 8 Inputs and 8 Relay Outputs

The Delta DVP16EH00R2 is a Delta DVP-EH2 PLC CPU powered by 100–240 V AC. It has 8 digital inputs rated at 24 V DC and 8 relay outputs. It monitors sensors and switches load control circuits in machine automation applications such as small conveyors, part counting and station control.

Inputs, outputs and addressing

The onboard inputs are addressed X0–X7 and the outputs Y0–Y7. The first digital expansion inputs start at X20 and outputs at Y20. When wiring an inductive sensor, photoelectric sensor or limit switch, check the signal level and the S/S input common. PNP and NPN sensors require different common wiring. For continuous measurements, consider the difference between analog and digital inputs when choosing a module.

The relay output drawing shows C0–C7 commons for Y0–Y7. Delta specifies a limit of 2 A per relay contact for resistive loads. Allow for inrush current and use suitable transient suppression when switching a contactor or valve coil. Check the panel schematic for fuse protection and protective grounding. Verify the emergency-stop function as part of the machine’s safety circuit.

High-speed counter inputs up to 200 kHz

The EH2 installation sheet specifies up to 200 kHz input bandwidth for X0/X1 and X4/X5. When using an incremental encoder, check the frequency limit for the selected counting mode, the A/B channel order and the signal level. For a differential line-driver encoder, use the input diagram to check whether an interface is needed. If the count changes unexpectedly when the motor starts, check for electromagnetic interference and review the encoder cable routing.

WPLSoft, ISPSoft and programming cable

Use WPLSoft or ISPSoft for PLC programming. Select DVP-EH2 as the project target. In ISPSoft, configure the serial connection in COMMGR. Save a copy of the existing ladder program and machine settings before making changes.

Connect through COM1 (RS-232, 8-pin mini-DIN) using DVPACAB230 (3 m) or DVPACAB215 (1.5 m). If the PC has no serial port, add a USB-to-RS-232 adapter. Install the adapter driver and select the COM port assigned by Windows. See Delta PLC cables for other connection options.

COM2 (RS-485) can be used for industrial communication. On an existing RS-485 Modbus link, record the station number, baud rate and parity. For a Modbus RTU connection to SCADA, read a known address after service to verify data flow.

Editor’s Note

Check the full label when buying used. Ask for the complete DVP16EH00R2 code and a close-up of the terminals. Identify the relevant C terminal in the drawing before connecting a load.

Back up the program first. With the machine in a safe state, save the program, serial settings and the order of the installed expansion modules.

Test the relay under load. With the Y LED on, verify that the relay switches a suitable test load. Cycle frequently used outputs several times.

Test the high-speed inputs separately. Monitor the input pair on the bench with a suitable signal. If using an encoder, verify that the count changes correctly in both directions.

Check the expansion addresses. After replacing the CPU, compare the first module’s X20/Y20 addresses with the old project’s I/O list.

Related Delta models

The DVP16EH00T2 is the transistor version with the same 8 inputs and 8 outputs. The relay-output DVP20EH00R2 has 12 inputs and 8 outputs, while the DVP32EH00R2 has 16 inputs and 16 outputs. The later DVP16EH00R3 also has 8 inputs and 8 relay outputs. Compare the terminal layout, program and installed expansion modules before replacing the CPU.

Internal references and PDF files

Delta DVP PLC PDF files · Delta DVP-EH2 installation and terminal sheet (PDF) · Delta DVP PLC series · Used Delta products

External references

Delta DVP-EH2 wiring sheet, 2009 edition (PDF) · Delta DVP PLC programming manual, EH2 table (PDF) · Delta DVP catalogue and programming cables (PDF)