Delta DVP16EH00T2

Delta DVP16EH00T2 | 16-Point Transistor Output PLC

The Delta DVP16EH00T2 is a 100–240 V AC PLC main unit from the Delta DVP-EH2 series. It has 8 digital inputs rated at 24 V DC and 8 NPN open-collector transistor outputs. It reads sensors, counts parts and switches compatible DC control loads in compact machine panels.

X0–X7 inputs and high-speed counting

The onboard inputs are addressed X0–X7. The S/S common connection sets the input circuit for sinking or sourcing. Check the PNP or NPN signal type against the panel diagram. When replacing an inductive sensor or limit switch, verify both the input voltage and the common connection.

Delta specifies 200 kHz input bandwidth on X0, X1, X4 and X5. When connecting an incremental encoder, check the A/B signal type, assigned input pair and frequency limit for the chosen high-speed counter mode. The encoder’s pulses per revolution and maximum shaft speed determine the required counting rate.

Y0–Y7 outputs and load selection

The Y0–Y7 outputs are rated in the 10 kHz class, and the output circuit operates at 5–30 V DC. Use the instruction sheet applicable to the hardware revision when selecting the load current. The earlier EH2 sheet linked below specifies 0.3 A per point at 40 °C for standard transistor outputs. The 2014 EH2 sheet’s electrical table specifies 0.5 A per point and 4 A per COM for resistive loads.

Use a suitable flyback diode or suppressor for a DC coil. Select a suitably rated interposing relay or driver for AC coils or higher-current loads. For a pulse-command servo application, verify the drive’s required pulse frequency and electrical input type. Delta models with 200 kHz outputs are listed below.

Programming software and cable

Program the DVP16EH00T2 with WPLSoft or ISPSoft. Select the DVP-EH2 CPU target. For an ISPSoft serial connection, configure and start the channel in COMMGR and select the same channel in ISPSoft. Record the original project and CPU firmware before servicing an existing machine. See the guides to ladder diagrams and PLC programming for help reading the program.

The PC connects through the PLC’s 8-pin mini-DIN COM1 / RS-232 port. Use a DVPACAB215 (1.5 m) or DVPACAB230 (3 m) serial cable. On a USB-equipped PC, use a suitable USB-to-RS-232 adapter with the serial cable. Install the adapter driver and select the COM port assigned by Windows. See Delta PLC cables and the guide to RS-232, RS-422 and RS-485 when selecting a connection.

Field communication and expansion

COM2 / RS-485 can communicate with an HMI or drive. For Modbus over RS-485, match the station address, baud rate and parity. Verify the existing project’s Modbus ASCII or Modbus RTU setting on the device at the other end.

Program capacity is 16 k steps. Compatible modules can bring an EH2 system to 512 total I/O points. Digital expansion inputs and outputs start at X20 and Y20. For 0–10 V or 4–20 mA measurements, consider a suitable module such as DVP04AD-H2. Check its channel settings and see the guide to analog and digital inputs.

Editor’s Note

Get a close-up of the label. When buying used, ask for photos showing the 00T2 suffix, hardware revision and output terminals.

Test the Y outputs under load. An output LED can light even when the channel can no longer sink current. Isolate the machine loads and test the outputs and C commons with a suitable DC load.

Check counting and pulse generation separately. If counts are lost at speed, check the input pair, counter mode and filter. For a drive command, measure the Y output frequency and signal level separately.

Check the expansion addresses. On a machine with expansion modules, compare the project’s addresses starting at X20 and Y20 with the actual module order.

Back up first if BAT.LOW is lit. Save the program, retained values and serial settings before switching off. Follow Delta’s battery replacement procedure.

Internal References | Related Delta Models

The DVP16EH00R2 has the same 8 inputs and 8 outputs with relay switching. The EH2 DVP20EH00T2 and DVP32EH00T2 support 200 kHz pulse output on Y0 and Y2. The DVP16EH00T3 belongs to the EH3 generation and combines the same 8/8 I/O count with high-speed pulse output. Compare terminals, output ratings, the project and expansion modules before changing the CPU.

Related Topics

See grounding and fuses for the panel supply, and NO and NC contacts for field signals. See safety relays for emergency stop and guard-door circuits.

OtomasyonAVM PDF and Series Links

Delta DVP PLC files · Delta DVP-EH2 hardware and terminal sheet (EN, PDF)

All Delta DVP PLC series · Used Delta models

External References

Delta DVP-EH2 hardware instruction sheet, 2014 (PDF) · Delta DVP-PLC programming manual, EH2 I/O and output frequencies (EN, PDF) · Delta ISPSoft and COMMGR serial connection guide (EN)