Delta DVP20EH00T

Delta DVP20EH00T | DVP-EH PLC with 12 inputs and 8 transistor outputs

The Delta DVP20EH00T is a PLC CPU in the original DVP-EH series. It runs on 100–240 V AC and provides 12 digital inputs at 24 V DC and 8 NPN open-collector transistor outputs. Delta’s detailed EH table lists 15,872 program steps. The CPU can read sensors and command two pulse-controlled axes in labeling and cut-to-length applications.

Digital inputs and two-axis pulse outputs

Inputs X0–X13 use octal addressing. X10 follows X7. Check the manual’s S/S wiring diagram for the installed NPN or PNP sensor type. An inductive sensor can detect a reference position and a photoelectric sensor can detect a passing product. For an incremental encoder, check signal levels and the X inputs assigned to the counter in the existing project.

Y0 and Y2 provide pulses at up to 200 kHz per axis. Delta’s pulse/direction wiring example pairs Y0/Y1 for the first axis and Y2/Y3 for the second. Check open-collector input compatibility, pulse mode and input current in the servo or stepper motor drive manual.

The Y0–Y7 transistor outputs operate at 5–30 V DC. The original EH instruction sheet specifies 0.30 A per point at 40 °C for standard switching and 30 mA for high-speed output. Check current draw and coil suppression for DC valves or interposing relays. For a run command to a variable frequency drive, use the drive’s digital input diagram. Check the cabinet’s fuses and grounding against the drawings.

Programming software and cable

WPLSoft is the first choice for reading, backing up and monitoring an existing EH ladder project. If using ISPSoft, verify that the installed version offers the original EH CPU target and configure the serial connection in COMMGR. Keep the original PLC project before conversion. After compiling, review positioning instructions and I/O assignments.

Connect the PC through COM1 RS-232. The DVPACAB2A30 cable uses an 8-pin mini-DIN connector at the PLC and DB9 at the PC. For a USB-only PC, use a compatible USB-to-RS-232 adapter and driver. Select the COM number shown in Device Manager.

If an HMI, drive or SCADA system uses Modbus over COM2 RS-485, record the station address, baud rate, parity and ASCII or RTU mode from the existing system.

Related Delta models

The DVP20EH00R is the same-generation model with 12 inputs and 8 relay outputs. The DVP32EH00T has 16 inputs and 16 transistor outputs. The DVP20EH00T2 belongs to EH2 and the DVP20EH00T3 belongs to EH3. Check the terminals, positioning instructions and expansion modules when changing the CPU. For analog measurements, check the signal range and channel settings of the DVP04AD-H module.

Editor’s Note

When buying used, read the full DVP20EH00T code on the side label and ask for a photo of the Y0–Y3 terminals.

If BAT.LOW is on, back up the program, retentive registers and axis settings before shutdown and battery replacement. Follow Delta’s battery service procedure.

Once power is isolated, photograph the wire numbers at S/S and the output commons before disconnecting them.

With the machine loads disconnected, check the Y0 and Y2 pulse signals individually on the bench. When troubleshooting the PLC, measure signal frequency and level as well as checking the LED.

Before returning the machine to production, verify the safety relay, emergency stop and axis reference sensors against the cabinet drawings.

Related topics and internal references

Industrial communications · Delta DVP PLC files · ISPSoft User Manual (English PDF)

Delta DVP-EH · Delta DVP PLC series · Delta main page

External references

Delta DVP-EH installation and wiring sheet (2006, PDF) · Delta DVP technical information and original EH model table (PDF) · Delta WPLSoft and ISPSoft FAQ