The Delta ASD-IF-EN0A20 converts position feedback from a compatible external encoder into Delta’s serial feedback format. It accepts A/B square-wave or analogue Sin/Cos signals and sends the processed data to the servo drive through CN2. Delta documents the box in the ASDA-A2R and ASDA-A3 manuals. Check the full drive and encoder model codes before ordering.
Input signals and connection path
A/B square wave The pulse input is rated at 5 V, with a maximum input frequency of 2 MHz. When selecting an incremental encoder, check the differential pairs, line-driver output and encoder output type against its data sheet.
Analogue Sin/Cos input The differential amplitude range is 0.4–1.2 Vpp and the maximum input frequency is 500 kHz. Check Sin, Cos and any reference signal on the analogue encoder or linear scale. For applications with Hall sensors, match their wiring to the motor diagram in the drive manual.
Connection path Connect the signal source to CN26 on the box. A suitable cable connects the box’s CN20 to CN2 on the drive. The box receives its nominal 5 V DC supply through this connection. On ASDA-A2R, CN5 provides a separate input option for a compatible square-wave external scale. Check both encoder connectors when selecting the Delta servo cable.
In a servo system, feedback reports motion from the servo motor or measurement scale. Direction and scaling affect axis positioning and the speed measured for the speed loop. Compare a known mechanical movement with the reported position change during commissioning.
PDF manuals
ASDA-A2R §3.11.3 · Signal converter, input specifications and pin assignments (English).
ASDA-A3 §11.6 · Converter specifications, indicators and CN26 wiring (English). Appendix B.12 lists the ASD-CNSC0020 20-pin connector as a separately ordered accessory.
Both documents use the same PDF addresses in the Delta Servo Manuals archive.
Editor’s Note
When buying a used box, ask for a clear photo of the ASD-IF-EN0A20 label and both sockets. Confirm whether the CN26 plug, CN20 plug and drive cable are included.
If there are no counts, check the cable and input mode first. With switch selection on the box, X1 selects A/B pulses and X2 selects Sin/Cos. In Drive Mode, the drive controls the selection.
If indicated position moves in the wrong direction, check mechanical travel and the feedback phase sequence together. Verify wire colours against the pin diagram.
If counts drop only at higher speeds, check input frequency, differential amplitude and shield termination. Repeat the same movement at low and higher speeds to compare readings.
During drive commissioning, verify direction and scale with a short move in a safe test setup. Then test homing and repeat the position measurement.