Delta DVP40ES200T – DVP-ES2 PLC with 24 Inputs and 16 NPN Outputs
The Delta DVP40ES200T is a compact PLC CPU in the Delta DVP-ES2 series. It uses a 100–240 V AC power supply and has 24 digital inputs at 24 V DC and 16 NPN transistor outputs. It has a 16K-step program capacity and removable terminals. Typical applications include packaging, conveyors and machine sequence control.
Digital inputs and transistor outputs
The built-in I/O uses octal addresses X0–X27 and Y0–Y17. When connecting limit switches or inductive sensors, wire the S/S input common according to the PNP or NPN sensor diagram. Use the model’s wiring drawing to connect the external 24 V DC auxiliary supply to the UP0/ZP0 and UP1/ZP1 terminals. Delta lists a 5–30 V DC switching range and a maximum of 0.5 A per output with a resistive load. For coils, also check the load current and suitable suppression.
Y0 and Y2 operate at up to 100 kHz. Y1 and Y3 operate at up to 10 kHz. When wiring a stepper motor drive for pulse-and-direction control, check the instruction’s output mapping and the drive’s input type. For encoders, check the high-speed counter mode and input pair. Delta’s 2024 sheet reports that ES200 CPUs manufactured after 2013 raised the specified limit on X1 and X3 from 10 kHz to 100 kHz.
Use compatible DVP-ES2/EX2 expansion modules to add field I/O. For example, the DVP08XM211N adds eight digital inputs and the DVP08XN211R adds eight relay outputs. Check the system I/O count, module order and power budget against the project.
Programming software, cable and serial communications
Use Delta WPLSoft or Delta ISPSoft to program the PLC. Delta’s cable guide lists the UC-PRG020-12A for connecting a PC’s USB port to COM1 (RS-232) on the PLC. Check the COM port assigned by Windows. For ISPSoft, select the connection through COMMGR.
COM2 and COM3 are built-in RS-485 ports. With compatible settings, they can communicate with an HMI or drive over Modbus RTU. Record the station address, baud rate and parity for each link. For projects that require built-in Ethernet, check the ports on the DVP40ES200TE.
Editor’s Note
Read the last letter of the model code when buying used. The DVP40ES200T has NPN transistor outputs. The DVP40ES200R has relay outputs. Check the machine’s output circuits and any pulse-and-direction axes before ordering a spare.
Isolate power, then photograph the S/S and UP/ZP terminals. Match the supplies and output groups to the drawing before transferring the terminal blocks.
Watch the load as well as the output LED during a bench test. Check the transistor output groups with a suitable low-voltage test load.
Test the programming connection on COM1 and the serial field connections on COM2 and COM3 individually.
Before swapping the CPU, back up the program, retained recipe data and serial port settings. Record the manufacturing date if the machine uses high-speed counters.
Related models and files
The DVP40ES200R has the same built-in I/O count with relay outputs. For transistor output applications, compare the DVP32ES200T and DVP60ES200T if the project needs a different input count.
Delta DVP PLC series · Delta PLC models · Used Delta products · Delta DVP PLC PDF files
External references · Delta DVP-ES2 Installation and Wiring Sheet (2024, EN and ZH) · Delta DVP-ES2 Programming Manual (2024, EN) · Delta PLC/HMI Cable Selection Guide (2019, EN)