Delta DVP12SA11T

Delta DVP12SA11T — DVP-SA PLC with 8 inputs and 4 NPN outputs

The Delta DVP12SA11T is a 24 V DC PLC CPU in the original DVP-SA series. It has 8 digital inputs (X0–X7), 4 NPN transistor outputs (Y0–Y3) and 7,920 program steps. The front panel has VR0 and VR1 adjustment pots and a BAT.LOW indicator. Compatible DVP expansion modules can add I/O.

In a labelling or feed machine, a photoelectric sensor can detect products and a limit switch can report the end of travel. The PLC can use these signals to send pulses to a compatible stepper motor drive or operate a DC-coil interface relay. Check the drive pulse input type and PLC I/O wiring together.

Digital input and NPN output wiring

The CPU supply range is 20.4–28.8 V DC. Connect the input S/S common to +24 V DC for NPN sensors or 0 V for PNP sensors. The NPN and PNP and sink/source guides show current direction.

The output groups are Y0/C0, Y1/C1 and Y2–Y3/C2. Connect the relevant C terminal to load supply 0 V and connect the load between supply positive and its Y output. Delta specifies 0.3 A per channel at 40 °C for transistor outputs and 30 mA per channel when Y0/Y1 operate as high-speed pulse outputs. Follow the manufacturer’s flyback diode guidance for DC coils.

High-speed pulses and front-panel adjustments

Delta’s installation sheet lists a high-speed pulse load condition of 32 kHz for Y0 and 10 kHz for Y1. The application manual specifies a 50 kHz upper limit for the special Y0 pulse function that uses M1133 and D1133. Check the drive input current and wiring when applying that programming limit. For encoder feedback, check the selected high-speed counter mode and its input assignments.

The front VR0 and VR1 pots can be enabled via M1178/M1179 and read through D1178/D1179. Their readings can provide a local delay or threshold adjustment. For external analog signals, select an analog input module compatible with the CPU.

Programming, cable and communication

Use WPLSoft or a version of ISPSoft that supports the original SA for PLC programming. Select the DVP-SA family. Delta’s SA sheet lists the DVPACAB2A30 PC serial cable for the front 8-pin mini-DIN COM1 RS-232 port. For a USB-equipped PC, use a suitable USB-to-RS-232 adapter with the serial cable. Check the DVP programming cable connection types. In ISPSoft, select the correct COM port through COMMGR.

COM2 RS-485 handles field communication. Delta’s sheet lists master and slave modes for COM2. The RS-232 and RS-485 ports use different electrical interfaces. For Modbus RTU, match the station address, speed, parity and stop bits to the connected device.

Editor’s Note

Read the full nameplate on a used CPU. DVP12SA11T is the original SA model and DVP12SA211T is the SA2 model. Delta lists 16K steps and two RS-485 ports for SA2. Select the matching CPU when migrating the project.

Back up the program and any required retained D values. If BAT.LOW is on, check the battery, retained data and real-time clock.

If Y2 and Y3 fail together, first check the C2 common’s 0 V connection with a multimeter. Y0 and Y1 have separate commons.

Start the pulse test at a low frequency. Safely prevent mechanical motion while checking the PLC output and the drive pulse input.

Turn each front adjustment pot and watch D1178 or D1179 online. If the value stays fixed, check the matching enable bit.

Related topics and PLCs

DVP12SA11R SA with relay outputs · DVP12SA211T SA2 with NPN outputs · DVP12SA211R SA2 with relay outputs · DVP12SC11T SC for positioning applications

Delta DVP-SA2 · Delta DVP PLC series · Used Delta PLCs · Delta main page

PDF files and manuals

Delta DVP PLC PDF files · Delta DVP-SA wiring and operation sheet (TR)

External references · Delta DVP-SA installation and wiring sheet (includes EN) · Delta DVP Application Manual for Programming (EN)