Delta DVP12SA211T
Delta DVP12SA211T PLC with 8 Inputs and 4 NPN Transistor Outputs
The Delta DVP12SA211T is a compact 24 V DC PLC in the DVP-SA2 series. It has 8 digital inputs, 4 NPN transistor outputs and 16K steps of program memory. Typical uses include pulse-controlled feeding, cutting, labeling and positioning machines.
On a labeling machine, a photoelectric sensor can detect an incoming product while an encoder measures how far it has traveled. At the labeling point, the PLC can send a pulse command to a stepper motor drive or a servo drive. Check the drive’s signal type, input voltage and required pulse frequency when assigning the pulse and direction terminals.
Power supply, digital inputs and NPN outputs
CPU supply • Nominal 24 V DC, operating range 20.4–28.8 V DC, CPU power consumption 1.5 W. Account for inrush current, expansion modules and field loads when sizing the 24 V DC power supply.
Digital inputs • Eight 24 V DC inputs at X0–X7. Connect the S/S common to 0 V for PNP sensors and to +24 V for NPN sensors. Check the label for the output type when connecting an inductive sensor or encoder. For an encoder, confirm the input assignment and frequency limit for the selected counter mode.
NPN transistor outputs • Y0–Y3 are sinking outputs that conduct toward 0 V. Delta specifies a load circuit range of 5–30 V DC and a resistive load limit of 0.5 A per output. The UP and ZP terminals require an external 24 V DC auxiliary supply. Check supply polarity and load wiring against Delta’s 12SA2-T diagram.
High-speed pulse outputs • Y0 and Y2 support up to 100 kHz, and Y1 and Y3 support up to 10 kHz. Assign the pulse and direction signals according to the motion instruction in use. During commissioning, also check the home reference input and direction of travel.
Expansion • Compatible Delta DVP expansion modules and Slim analog modules can be added on the right. The 12SA2 CPU also has a left-side connector for high-speed modules. Check the exact CPU and module codes for compatibility before adding a weighing module such as the DVP01LC-SL.
WPLSoft, ISPSoft and programming cable
Use WPLSoft or ISPSoft to write ladder logic and transfer it to the CPU. Select the DVP-SA2 family for a new project. For an ISPSoft connection, configure the serial channel in COMMGR.
The UC-PRG020-12A cable connects the PC’s USB-A port to the PLC’s COM1 RS-232 port through its 8-pin mini-DIN plug. Install the Delta programming cable driver and select the COM number assigned by Windows. COM2 and COM3 support RS-485 Modbus communication with an HMI, drive or instrument.
Editor’s Note
When buying a used CPU, confirm the full DVP12SA211T code on the label. Check photos of the COM1 socket, power plug and UP/ZP terminals.
If the Y LED is on and the load stays off, check the UP/ZP auxiliary supply with a multimeter. Then check that the load is wired for an NPN sinking output.
If the drive receives no pulses, compare the program’s output address with the drive’s pulse input type. The Y LED cannot show pulse frequency. Test the pulse and direction commands separately at low speed with the travel area clear.
If communication drops when the motor starts, check that pulse and RS-485 cables run separately from motor wiring. Inspect the shield connections and panel grounding.
Before replacing the CPU, save the original project file, expansion module order and settings for COM2 and COM3. Verify the home and limit inputs during the first machine test.
Related PLC models
DVP12SA211R • 8 inputs and 4 relay outputs. DVP28SA211T • 16 inputs and 12 NPN transistor outputs. DVP28SA211R • 16 inputs and 12 relay outputs. DVP12SE11T • SE CPU with Ethernet, 8 inputs and 4 NPN outputs. For a new panel, you can also review Derell B Series PLCs against the project’s I/O and communication requirements.
Related topics and PDF files
Delta DVP PLC PDF files · Delta DVP PLC series · Used Delta PLC models · Used PLCs and CPUs · Delta main page