Delta DVP-EH3-L

Delta DVP-EH3-L — 32-point PLC with left-side expansion

The Delta DVP-EH3-L range covers the PLC CPUs in the Delta DVP-EH3 family that support high-speed expansion on the left. Both models have a 100–240 V AC supply, 16 digital 24 V DC inputs, 16 digital outputs and a 30,000-step program capacity. Compatible analogue and communication modules can be mounted on the CPU’s left side.

R3-L relay and T3-L transistor models

The DVP32EH00R3-L has 16 relay outputs. When switching a contactor, interposing relay or valve coil, check the load type, inrush current and the rating of the output common group.

The DVP32EH00T3-L has 16 transistor outputs. For a drive that needs a high-speed pulse command, Delta’s catalogue specifies four axes at 200 kHz for 32-point EH3 units manufactured after 2014. Check the manufacturing date and the pulse channels on a used unit.

The built-in PLC I/O is addressed in octal as X0–X17 and Y0–Y17. When connecting an inductive sensor, check the S/S input common against the sensor’s PNP or NPN signal. Both CPUs support high-speed counting. For an encoder, check the A/B channels, input level and counting frequency allowed by the selected counter mode.

The -L suffix and left-side expansion modules

The -L suffix identifies the left-side high-speed expansion interface. The standard DVP32EH00R3 and DVP32EH00T3 have the same built-in I/O count. For a replacement in a cabinet with a left-side module, match the -L suffix in the ordering code. Use the appropriate compatibility table for modules on each side of the CPU.

The DVP04AD-SL is a compatible four-channel analogue input module. For 0–10 V or 4–20 mA applications, check the channel type and PLC scaling together. The DVPEN01-SL is a left-side Ethernet module that adds Modbus TCP communication.

Programming software, cables and ports

Both CPUs can be programmed with WPLSoft or ISPSoft. For an existing Ladder project, use the software that matches the source file and check the EH3 CPU selection. ISPSoft uses COMMGR for the serial channel. Read the running PLC and save a backup before making program changes.

The PC connects to the CPU’s COM1 RS-232 port. Delta’s cable guide lists the UC-PRG020-12A (2 m) for a PC with USB and the UC-MS030-01A (3 m) for a PC with a serial port. When using the USB cable, select the COM number assigned by its driver.

COM2 is an RS-485 port. When setting up field communication with an HMI or drive, check the Modbus and RS-485 settings together. In a Modbus RTU project, match the station address, baud rate, parity and register addresses. If the machine has a SCADA connection, save the address map alongside the project backup.

Editor’s Note

Check the label and the left side together. When buying used, request photos of the full ordering code and left expansion connector. Look for bent pins and broken latches.

Record module order before removal. Photograph the codes and positions of the left- and right-side modules and save the project settings.

Read the program first. Back up machine recipes, scaling values and communication settings as well.

Test according to the output type. For the relay model, confirm that the contacts switch a suitable low-voltage test load. On the transistor model, check the output commons and pulse channel against the wiring diagram.

Test the left-side module at the bench. With machine loads disconnected, confirm that the CPU recognises the module and reads the measurement or communication data correctly. Check protective grounding before power-up.

Internal references and PDF files

Delta DVP PLC PDF files · Series catalogues, hardware documentation and connection guides.

Delta DVP-EH3 series · Delta PLC models · Used Delta equipment

External references

Delta DVP PLC catalogue · R3-L and T3-L comparison, left-side expansion and the manufacturing-date footnote.

Delta PLC/HMI cable selection guide · Cable options and wiring diagrams for both EH3-L models in section 1.10.

Delta DVPEN01-SL product information · EH3-L compatibility and Modbus TCP specifications.