Delta DVP32EH00R3

Delta DVP32EH00R3 · DVP-EH3 PLC with 16 Inputs and 16 Relay Outputs

The Delta DVP32EH00R3 is a compact PLC main unit from the DVP-EH3 family. It has a 100–240 V AC supply, 16 digital inputs rated for 24 V DC, and 16 relay outputs. Its 30,000 program steps and 12,000 words of data-register memory support sequencing, part counting and load control in packaging, labelling and assembly machines.

Inputs, relay outputs and addressing

The inputs are addressed X0–X7 and X10–X17. The outputs are Y0–Y7 and Y10–Y17. In octal addressing, X10 comes after X7. When connecting an inductive sensor, photoelectric sensor or limit switch, check the S/S input common against the PNP or NPN signal circuit.

The relay outputs are grouped under C0–C3. For resistive loads, Delta specifies 2 A per point and 5 A per common. For a contactor or valve coil, check the load-specific rating, coil inrush current and appropriate transient suppression. Check fusing and short-circuit protection for the output group.

High-speed counters and related Delta models

The CPU supports four hardware counters in the 200 kHz class. When connecting an encoder, check the A/B phases, signal level and input assignments for the selected counting mode. The R3 relay outputs are for on/off control. For high-speed pulse commands to a servo drive or stepper motor drive, check the output specifications and hardware revision of the DVP32EH00T3, which has the same I/O count.

The DVP40EH00R3 provides 24 inputs and 16 relay outputs. The DVP32EH00R3-L has the same I/O count and supports left-side high-speed expansion. Check the installed module positions and the full model suffix before selecting a replacement CPU.

Programming software and connection cable

Use WPLSoft or ISPSoft for PLC programming and ladder editing. Select the DVP-EH3 project target. For ISPSoft, set up the serial channel in COMMGR.

COM1 is the 8-pin mini-DIN RS-232 port for the PC connection. Use UC-PRG020-12A with a USB-equipped PC. Install the driver and select the COM number assigned by Windows. For a PC with a physical RS-232 port, use the UC-MS020-01A serial cable.

COM2 is the RS-485 field port. When connecting an HMI panel or a Modbus RTU device, match the station address, baud rate, parity and serial data format. For Ethernet, the compatible DVP-FEN01 option card provides Modbus TCP. Delta specifies EH3 firmware V1.12 or later for this card.

Editor’s Note

Start with the full nameplate code. Pay attention to R3, T3 and R3-L. Photograph the terminals and fitted cards before disconnecting anything.

On a used unit, read the program through COM1 and test field communication through COM2 separately. Monitor each input to confirm it appears at the expected address.

When a relay output LED turns on, verify that the contact switches with a suitable test load. Check frequently used outputs and each C0–C3 common individually.

If BAT.LOW is lit, back up the program and required retained data before a planned shutdown. Follow the Delta instruction sheet for the hardware when servicing the battery.

If the PLC resets or the count jumps when a contactor operates, check the supply under load. Inspect signal cable routing, panel grounding and the drive’s EMC filter, if fitted.