Delta DVP16EH00T
Delta DVP16EH00T — 8-input, 8-transistor-output PLC
The Delta DVP16EH00T is a 16-point PLC CPU from the original Delta DVP-EH series. It runs from a 100–240 V AC supply and provides 8 digital 24 V DC inputs, 8 transistor outputs and a 15,872-step program capacity. Applications include small feed stations, part sorting and existing machine control cabinets.
Digital inputs and output terminals
The built-in PLC I/O uses addresses X0–X7 and Y0–Y7. Check the electrical compatibility of field devices such as inductive sensors, photoelectric sensors and limit switches. Wire the S/S input common to match the sensor’s PNP or NPN output.
The CPU uses open-collector transistor outputs. Delta specifies 5–30 V DC for the load circuit. Follow the terminal drawing for the C0–C7 output commons. For a valve or contactor coil, compare the coil current with the output rating. Use a suitable interposing relay and suppression device as appropriate for the load.
If the machine uses an encoder or sends a high-speed pulse command to a drive, record the X and Y addresses in the existing program. Delta’s original EH table gives its Y0/Y2 pulse output note for the DVP20EH00T and DVP32EH00T. Before using a DVP16EH00T in a motion application, verify the output channel and frequency for the specific hardware.
Programming software and cable
WPLSoft is used to read, back up and monitor the original EH Ladder project. Select the DVP-EH CPU and save a dated copy from the running PLC before making program changes. If using ISPSoft, verify that the installed version offers the original EH target and can read from the CPU. Configure its serial channel in COMMGR.
The computer connects to the CPU’s COM1 RS-232 port. Delta’s technical document lists the DVPACAB230 (3 m) and DVPACAB215 (1.5 m). If the computer has only USB ports, use a suitable USB-to-RS-232 adapter and select the COM number assigned by its driver.
COM2 and field communications
COM2 is an RS-485 port. When taking over field communications with an HMI or variable frequency drive, document the Modbus and RS-485 settings. Check which mode the machine uses, Modbus RTU or Modbus ASCII, and record the station address, baud rate, parity and register addresses.
Related Delta models and expansion
The DVP16EH00R is the original-generation model with 8 inputs and 8 relay outputs. The DVP20EH00T has 12 inputs and 8 transistor outputs. The DVP16EH00T2 belongs to EH2 and the DVP16EH00T3 to EH3. Both have 8 inputs and 8 transistor outputs. When changing generations, compare the program, output terminals and installed modules.
The original EH expansion table lists the DVP08HP11T digital I/O expansion and the DVP04AD-H analogue input module. If the machine reads an analogue signal, record its channel settings and PLC scaling as well as the module code.
Editor’s Note
Read the full label first. When buying used, look for the complete DVP16EH00T code and its final T suffix in the label photo.
Check the BAT.LOW indicator. Read the program at the bench and save the machine’s recipes and retained register values.
Test all eight outputs. With the machine loads disconnected, check each Y output through its own common using a suitable low-voltage DC test load.
Include the expansion module. When testing a replacement CPU, confirm that the project recognises the module and reads its field signal correctly.
Test both serial ports separately. Read the program through COM1 and check that the field device responds on COM2. Inspect the terminals and protective grounding before applying power.
Internal references and PDF files
Delta DVP PLC PDF files · Hardware documentation, catalogues and connection guides.
Original DVP-EH series · Delta PLC models · Used Delta equipment
External references
Delta DVP-EH hardware and wiring sheet · The 16EH terminal drawing, supply and serial ports are on PDF page 1.
Delta DVP PLC technical information · Exact model on PDF page 20, program capacity on page 14, and software and cables on page 22.