The Delta DVP15MC11T is a 24 V DC motion controller in the Delta DVP-MC series with 16 digital inputs and 8 NPN transistor outputs. It runs the project on its own CPU and controls up to 24 real axes through the Motion port. Delta’s model table gives a total capacity of 32 axes, including real and virtual axes. The DVP15MC11T-06 variant supports 6 real axes and 16 total.

Motion port, CANopen and axis control

The Motion/CAN2 port controls servo drives that support the CANopen DS402 profile. The CANopen/CAN1 port handles general DS301 field communications. Check the full drive model, drive profile and applicable EDS file when choosing a drive. Delta lists three CANopen cables in the ASDA-A2-M drive wiring diagram, including the UC-CMC010-01A. See the CANopen guide for the network principles.

Single-axis instructions cover velocity, position, torque and homing. Electronic gearing, electronic cams and rotary cut can synchronize axes for coordinated motion. The manual specifies linear interpolation on up to 8 axes and circular interpolation on up to 3 axes. Set the synchronization cycle for the actual axis count, network load and motion task execution time.

Digital I/O, encoders and expansion

The supply range is 20.4–28.8 V DC. Digital inputs are grouped as 00–07 and 10–17, with S0 and S1 as their commons. Follow the appropriate input diagram for PNP or NPN sensor wiring. The encoder interface supports two incremental encoder connections and one SSI absolute encoder. In a cutting machine, for example, the feed encoder can track material position while an electronic cam ties the cutting axis to that position.

Select compatible DVP-S expansion modules for the right- or left-side connection. The left side supports compatible high-speed modules. The right side can take digital I/O modules such as the DVP08SM11N. Check the manual for the module type, layout and power budget.

Programming software and Ethernet cable

Use Delta CANopen Builder for the motion project. Connect the PC to LAN1 or LAN2 using an RJ45 Ethernet cable. In CANopen Builder, use the existing IP address of the connected port. LAN1 and LAN2 are independent interfaces with separate IP settings. Delta’s manual documents configuration, execution and cam file downloads through either Ethernet port.

Use Modbus TCP over Ethernet for an HMI or supervisory controller and RS-232 or RS-485 for serial field devices. On a serial link, match the station address and data format to the other device. See Modbus over RS-485 for the serial network principles.

Editor’s Note

When buying used, read the complete label. The DVP15MC11T and DVP15MC11T-06 look similar. Record the machine’s real axis count before choosing a replacement.

Before replacing the controller, back up the CANopen Builder source project, node addresses, axis parameters and any electronic cam or G-code files.

Label the LAN1, LAN2, CANopen and Motion cables in the panel. If a link fails, check the port label and the cable pinout first.

The Motion port has a built-in 120 Ω termination resistor. Check the termination at the far end of the network against Delta’s wiring diagram.

Verify axis-to-node assignments before enabling motion. At the first axis test, check direction, the homing switch and travel limits at low speed.

Related models and files

The DVP10MC11T is another CANopen motion controller in the family. The DVP50MC11T family uses EtherCAT for motion. For pulse-input drives, compare the DVP-PM and DVP24SV11T2 pages. Consider the drive network, encoder type and project files together when choosing a replacement.

Delta DVP PLC series · Delta PLC models · Used Delta automation equipment · Delta DVP PLC files

External references · Delta DVP15MC Operation Manual (2016, EN) · Delta DVP PLC Series Catalogue (2024, EN)