Delta DVP-PM: Programmable Motion and Position Controllers

Delta DVP-PM is a motion-controller family within the Delta DVP PLC series range, combining machine sequencing with position control. Alongside a PLC sequence program, it performs positioning and model-dependent motion tasks. It can command a servo motor drive or stepper motor drive when the controller output and drive command interface are compatible.

The 10PM and 20PM documents specify 64k program steps. The controllers covered here with the 00 supply code are in the 100–240 V AC class; check the complete nameplate before wiring. Do not confuse the auxiliary 24 V output with the main supply input. The distinction between speed and position control helps establish the motion functions required by the machine.

DVP10PM and DVP20PM model differences

DVP10PM00M targets standard motion applications, with four main axes supporting high-speed pulse output up to 1 MHz. DVP20PM00D and DVP20PM00DT provide two axes, while DVP20PM00M provides three axes of differential motion output up to 500 kHz. Do not transfer all 10PM axis specifications to 20PM, or assume that 20PM G-code functions are available on 10PM.

DVP20PM00D has relay-type normal outputs Y0–Y7; DVP20PM00DT has transistor-type normal outputs. These digital outputs serve a different purpose from the FP/RP differential axis terminals. Select pulse frequency, wiring and pulse/direction mode against the controller, drive and mechanical transmission requirements.

Programming software

PMSoft is the programming tool for DVP-PM. WPLSoft and ISPSoft are not direct PM project editors. PMSoft handles model-supported sequence programs, motion programs, parameters, transfer and online monitoring. On DVP20PM, the O100 main program and motion subprograms have distinct roles.

Depending on the model, DVP20PM supports functions including G-code/M-code, linear and circular interpolation, and electronic cam. Do not assume that all of these functions exist on DVP10PM. Select the exact controller in the project and match axis count, firmware and PMSoft instruction support.

Programming cable, COMMGR and communication

Serial programming can use the COM1 8-pin Mini-DIN RS-232 port. DVPACAB2A30 connects a computer’s 9-pin RS-232 port to the PM controller. A computer with USB can use it with a suitable USB-to-RS-232 adapter and driver. The manufacturer’s PM cable selection also lists the UC-PRG020-12A USB-to-RS-232 programming cable.

For PMSoft communication, select the correct COM port and an RS232 driver in COMMGR. Baud rate, data bits, parity and stop bits must match the controller. The differences between RS-232, RS-422 and RS-485 mean that matching connector shapes alone do not establish cable compatibility. This serial connection is not a direct native USB connection to the PM.

For COM2 Modbus/RS-485 communication, match the device address and Modbus RTU or Modbus ASCII configuration. A supported DVP-FPMC card provides Ethernet/CANopen options when installed; do not assume built-in Ethernet on a controller without the required card.

Encoders, homing and axis checks

When connecting an encoder, verify signal levels, A/B phases and the Z/PG reference where applicable. Incremental encoder resolution and line-driver signalling must suit the selected input. Incorrect electronic gearing or mechanical scaling can produce the wrong travel distance even when the motor rotates normally.

Test homing direction, approach speed and limit switches separately during commissioning. MPG, JOG and automatic motion must follow the same direction and travel-limit rules. DVP20PM can operate independently or as a motion extension in compatible systems; verify the host CPU and extension arrangement by complete model code.

Editor’s Note

When buying a PM controller, establish more than the axis count. Confirm the complete model, normal output technology, motion terminals and the controller type used by the existing project.

Back up the program and axis parameters before downloading a test project. Save electronic gearing, homing offsets, cam tables and required retained data separately as needed.

Make the first movement at low speed over a safe, limited distance. Compare the commanded pulses with actual travel; do not change wiring at random to correct a direction problem.

Drive-side auto-tuning does not replace mechanical scaling and homing setup in the PM controller. Monitor motor current, drive alarms and following error together.

If pulses are lost or counts are unstable, check shielded wiring, signal references and grounding. Consider interference where power and signal cables share the same route.

Do not rely solely on a software STOP instruction for emergency stopping. Assess an appropriate safety relay and stopping arrangement for the machine risk. Disconnect power before board repair and test communication, digital I/O and each axis separately.

PDF documents and related topics

Series archive: Delta DVP PLC files. Use the PMSoft user manual for software operation and the DVP-PM programming manual for program structure. Installation documents: DVP10PM multilingual instruction sheet · DVP20PM multilingual instruction sheet, including Turkish.

Navigation: Delta DVP PLC series · Delta PMSoft · Delta COMMGR · Delta PLC category · Used Delta equipment.

External references

Delta manufacturer introduction to DVP-20PM and PMSoft · DVP-PM G-code support · Delta PLC/HMI cable selection guide, DVP-PM section.


Refine Search