Delta DVP20PM00M three-axis motion control PLC

The Delta DVP20PM00M is a 100–240 V AC PLC and motion controller in the Delta DVP-PM series. It provides differential pulse outputs of up to 500 kHz on each X, Y and Z axis. Paired with a compatible servo drive or a pulse-input stepper motor drive, it can control cutting, feeding and multi-axis positioning.

Axis outputs and terminals

X uses FP0± / RP0±, Y uses FP1± / RP1± and Z uses FP2± / RP2±. Match the pulse/direction or CW/CCW format to the drive. The pulse frequency affects the commanded speed. Check the drive’s electrical input specifications and the differential pairs against the line-driver signal guidance.

X0–X7 are 24 V DC digital inputs. For Z-axis motion functions, X0 = DOG2, X1 = LSP2, X2 = LSN2 and X3 = PG2. Use the axis terminal diagram when checking limit switches, homing and inductive sensor signals. Check the roles of the A/B phases and reference signal when working with encoders or a handwheel.

Y2 and Y3 are low-speed transistor outputs. Y4–Y7 are relay outputs. The Z-axis FP2/RP2 pairs occupy the Y0/Y1 positions on the terminal block. Y2 (CLR2) provides the Z-axis drive error-counter clear signal. The PLC input and output layout varies by model. If you are moving wiring from a DVP20PM00D, check the Z-axis terminals and load types against the new diagram.

PMSoft, programming cables and communication

Select the model in Delta PMSoft and configure the connection driver in COMMGR. PMSoft handles ladder logic and motion programs. Use G01 for linear and G02/G03 for circular interpolation. G17 (XY), G18 (XZ) and G19 (YZ) select the working plane.

COM1 is the 8-pin mini-DIN RS-232 programming port. Use UC-PRG020-12A for a USB connection or UC-MS020-01A for a PC with DB9 RS-232. Delta’s programming manual also shows the DVPACAB2A30 pinout. COM2 supports RS-485 Modbus. Match Modbus ASCII or Modbus RTU settings to the connected device. Refer to the differences between RS-232 and RS-485 when choosing a cable.

Editor’s Note

Read the full DVP20PM00M code on the label. The D and DT models look similar and use different output terminals.

Before accepting a used unit, check the RUN/ERR indicators and PMSoft connection. Ask for a backup of the existing project and axis parameters.

Test the three axes individually. Pay particular attention to the Z-axis drive command and monitor the X0–X3 input states in the software.

A cable fault can look like a failed controller. Check shielding, grounding and possible electromagnetic interference. Use a multimeter for the supply and an oscilloscope suitable for differential measurements for the high-speed pulses.

After replacing a drive, check the travel per pulse and the speed and position control settings again. Secure the movement area before testing at low speed.

PDF manuals

See Delta DVP PLC files for the installation sheet, 20PM programming manual, PMSoft guide and cable selection guide.

20PM installation sheet (includes Turkish) · DVP-PM programming manual (EN) · PMSoft user manual (EN)

Related topics and models

DVP20PM00D and DVP20PM00DT are two-axis 20PM models. DVP10PM00M is a separate controller in the same family. DVP-FPMC is the optional Ethernet/CANopen card. For a module-based option, see the DVP01PU-S positioning module.

DVP20PM00M · Delta DVP-PM · Delta DVP series · Delta PLC · Used Delta automation