Delta DVP-MC
Delta DVP-MC Multi-axis Motion Controllers
Delta DVP-MC is a family of 24 V DC controllers combining PLC logic with multi-axis servo motion control. Packaging, printing, cutting, winding and synchronized handling applications use the controllers to coordinate multiple servo motors and compatible servo drives. Select the controller together with its motion network and engineering environment.
DVP10MC, DVP15MC and DVP50MC differences
DVP10MC11T provides CANopen-based control of up to 16 real axes and includes 8 digital inputs and 4 NPN outputs. Its PLC logic and MC motion sections use separate processors, so backups must cover both sections.
DVP15MC11T uses a CANopen motion network for up to 24 real axes, with 16 digital inputs and 8 NPN outputs. Its general CANopen communication port has a separate role from the CANopen Motion port used for servo synchronization.
DVP50MC11T uses an EtherCAT motion network and includes 16 digital inputs and 8 NPN outputs. The manufacturer’s 2020 archive manual specifies 24 real axes for the standard 11T/P and a separate 32-axis total for real, virtual and encoder axes. Later hardware, firmware and order codes must follow their applicable document revision. Variants such as -06, -04S and -16S have different capacity and multi-axis instruction support.
Programming software
DVP10MC11T: program its PLC logic with WPLSoft or ISPSoft and its MC motion section with CANopen Builder. Uploading the ladder program alone does not back up the complete motion project.
DVP15MC and DVP50MC: ISPSoft supports logic and motion development through its DVPxxMC support, with COMMGR managing connections. Older 15MC/50MC manuals and projects also use CANopen Builder. Match the existing project, CPU firmware and engineering software version before conversion. A project mentioning CANopen Builder does not change the 50MC EtherCAT motion interface into a CANopen interface.
Programming cable and PC connection
For Ethernet-based motion project transfer, connect the PC to the controller’s Ethernet port using RJ45 CAT5e or better network cable. The two DVP15MC Ethernet interfaces may have separate IP settings. Check the PC network range, selected adapter and target port. Ethernet, CANopen and EtherCAT sockets may share the RJ45 shape while serving different functions.
The DVP10MC PLC logic section can also be accessed through COM1 RS-232. This requires a DVP serial programming cable matching the PLC-side 8-pin port pinout. A PC without a serial port needs a suitable USB-to-RS-232 adapter and driver. Do not apply the same cable directly to the 15MC/50MC COM/SSI terminal arrangement. Ethernet access does not require a USB-to-serial converter.
HMI or SCADA data exchange can use supported Ethernet protocols or Modbus RS-485. Define engineering access, field data exchange and the synchronized motion network separately in the project.
Servo motion network cables
Use suitable CANopen cables such as UC-CMC003-01A or UC-CMC010-01A for CANopen Motion. Preserve the specified topology and end termination; TAP-TR01 is used where applicable. For the DVP50MC EtherCAT Motion network, manufacturer examples include UC-EMC003-02C / UC-EMC010-02C EtherCAT cables.
Verify the complete servo drive code, motion protocol and supported firmware. A conventional high-speed pulse output connection is different from CANopen or EtherCAT motion control. Drives with the same brand and power rating may have different communication options.
Encoders, homing and field inputs
Select the encoder interface together with signal level and resolution. Incremental encoders and absolute encoders do not use interchangeable connections; distinguish SSI from A/B/Z inputs. Match the encoder supply to the port’s permitted value.
Configure the home position and travel limits to suit the machine. Check output type, common terminal and active level for limit switches, inductive sensors and photoelectric sensors. Detecting a home input and moving safely in the correct reference direction are separate commissioning checks.
Commissioning and mechanical matching
After communication is established, assess auto-tuning and position-loop gain against the mechanical system. Set torque limits and torque control for the load. An incorrect planetary gearbox ratio, encoder resolution or electronic gearing can produce the wrong travel even when the network is healthy.
Design the emergency stop circuit with the required safety relay or appropriate safety system; a standard motion program alone is not a safety function. Cable shields and grounding affect communication stability and feedback signal quality.
Manuals and technical files
Use Delta DVP PLC files for model manuals, motion instructions and wiring documents. Preserve the PLC project, motion project, axis settings, CAM/G-code files and relevant servo parameters together.
Editor's Note
Do more than check the RUN indicator before buying a used controller. Record its complete order code and firmware, and establish whether the motion project is available. A 10MC ladder backup does not establish that the CANopen Builder motion project is available.
Make the first motion test at low speed in a controlled area with the stopping system ready. Verify direction, the home input and the effect of limits before enabling coordinated multi-axis operation.
For CANopen interruptions, inspect node addresses, baud rate, cabling and termination. For EtherCAT, check the correct IN/OUT sequence and network state of each device. The two networks require different checks.
Do not immediately increase gain when an axis misses its target. Check mechanical backlash, gearbox ratio, electronic gearing, encoder resolution and the motion cycle together. Avoid masking a mechanical fault with tuning.
Inspect the board with power removed. Record existing settings before changing an IP address, axis mapping or servo parameter on a working machine. A replacement MC with a similar housing does not make the machine ready to run.