Delta DVP40ES200RM

Delta DVP40ES200RM – ES2 PLC with SD slot, 24 inputs and 16 relay outputs

Delta DVP40ES200RM is a 100–240 V AC CPU in the DVP-ES2 series. It has 24 digital inputs at 24 V DC, 16 relay outputs and a 16K-step program capacity. It shares the I/O layout of the DVP40ES200R. The RM model adds a built-in SD card slot.

Digital inputs, relay outputs and commons

X0–X27 use octal addressing and share the S/S input common. Wire S/S for the PNP or NPN sensor circuit in use. Inductive sensors and limit switches can provide position feedback on conveyors and packaging machines. The input table lists 100 kHz for X0–X3, 10 kHz for X4–X7 and 60 Hz for X10–X27. Delta notes that the X1 and X3 ratings increased from 10 kHz to 100 kHz for units manufactured after 2013. For an encoder, check the high-speed counter input assignment and the limit of the selected counting mode.

The Y0–Y17 relay outputs are grouped in fours. The output commons are C0 (Y0–Y3), C1 (Y4–Y7), C2 (Y10–Y13) and C3 (Y14–Y17). The sheet lists contact voltages below 250 V AC or up to 30 V DC. Delta specifies 2 A per output and 5 A per common for resistive loads. Relay response is about 10 ms, and the maximum switching frequency is 1 Hz. For coil loads, check the relay contact life curve and inrush current. For pulse control, see the transistor-output DVP40ES200T.

Programming software and cable

Use WPLSoft or ISPSoft and select the DVP-ES2 target. The UC-PRG020-12A connects a USB-equipped computer to the PLC’s COM1 RS-232 8-pin mini-DIN socket. The UC-MS010-02A is an option for computers with an RS-232 serial port. After installing the USB cable driver, select the Windows COM number in WPLSoft communication settings or in the COMMGR channel for ISPSoft. See DVP programming cables for the available options.

RS-485 communication and I/O expansion

COM2 and COM3 are RS-485 ports. One can serve an operator panel and the other a drive network using Modbus RTU. Assign a unique station address to each device and match the baud rate, parity and stop bits across the network. Check signal ground and termination against the RS-485 wiring diagram.

All 40 onboard points are digital. Choose a compatible analog I/O module to read pressure or send an analog speed reference to a drive. Delta specifies support for up to 256 total I/O points with compatible expansion modules. Check the power budget and module layout for the planned configuration.

Editor’s Note

Check the full model label. When buying used, ask for photos of the DVP40ES200RM label, SD slot and removable terminal blocks. If the machine uses a card, check its condition and purpose against the maintenance records.

Test all four relay groups. The Y LED shows the PLC command. Use a suitable 24 V DC test load and a multimeter to test an output in each group. This checks both the common and the relay contact.

Account for coil loads. Add the currents of the loads sharing a common. Fit a suitable diode to a DC contactor coil or use the specified suppressor for an AC coil.

Check the serial ports separately. Connect the programming cable to COM1. Then record the COM2 and COM3 settings and test communication with a device on each RS-485 network.

Back up before replacing the CPU. With the machine in a safe state, save the project, communication settings and retained data. Back up the SD card contents if the machine uses a card.

Related topics and similar PLCs

DVP40ES200R standard 24 inputs/16 relays · DVP40ES200T 24 inputs/16 NPN outputs · DVP40ES200RE Ethernet, 24 inputs/16 relays · DVP60ES200R 36 inputs/24 relays

Delta DVP PLC series · PLC input and output modules · Used Delta PLCs · Delta main page