Delta DVP60ES200R

Delta DVP60ES200R ES2 PLC with 36 Inputs and 24 Relay Outputs

The Delta DVP60ES200R is a compact 100–240 V AC PLC in the DVP-ES2 series. It has 36 digital inputs, 24 mechanical relay outputs and 16K steps of program memory. It suits conveyor, packaging and assembly lines with many sensors, valves and control circuits in one panel.

On a conveyor, photoelectric sensors can detect passing products while inductive sensors report mechanism positions. The PLC can then command a valve or contactor coil as the sequence advances. The relay outputs are arranged in groups of four. The Y LED shows the command, and the corresponding C common terminal supplies the load circuit.

Power supply, inputs and relay outputs

CPU supply • 100–240 V AC, 50/60 Hz. The digital inputs use 24 V DC signals. Show the AC CPU supply and the 24 V DC sensor supply separately in the panel diagram.

Digital inputs • Thirty-six inputs at octal addresses X0–X43. Connect the S/S common to 0 V for PNP sensors and to +24 V for NPN sensors. For high-speed counting, check the encoder signal level, input assignment and counter mode together. Delta specifies a 100 kHz counting limit for X1 and X3 on ES200 units manufactured after 2013.

Relay outputs • The twenty-four outputs at Y0–Y27 are arranged in C0–C5 common groups. Delta specifies a resistive load limit of 2 A per output and 5 A per common group. The maximum switching frequency is 1 Hz. For contactor and valve coils, check the relay contact’s inductive load conditions and use suppression suited to the coil.

Output groups • C0 Y0–Y3 · C1 Y4–Y7 · C2 Y10–Y13 · C3 Y14–Y17 · C4 Y20–Y23 · C5 Y24–Y27.

Expansion • Add compatible Delta DVP expansion modules for additional inputs and outputs. Delta specifies up to 256 digital I/O points, including the built-in points, in a supported configuration. For pressure, temperature or level measurement, select a DVP analog module that matches the signal type.

WPLSoft, ISPSoft and programming cable

Use WPLSoft or ISPSoft to write ladder logic, transfer it to the CPU and monitor I/O online. Select the DVP-ES2 family in the project. When using ISPSoft, configure the serial communication channel in COMMGR.

UC-PRG020-12A programming cable • Connect the USB-A end to the PC and the 8-pin mini-DIN plug to the PLC’s COM1 RS-232 port. Install the Delta cable driver and select the COM number assigned by Windows. Match the serial settings to the installed CPU.

Field communication • COM2 and COM3 can connect to an HMI, drive or instrument using RS-485 Modbus. For built-in Ethernet with the same I/O count, see the DVP60ES200RE.

Editor’s Note

When buying a used CPU, confirm the full DVP60ES200R code in the photos. Check the removable terminal blocks, AC supply terminals and COM1 socket.

If four outputs fail together, start with the supply and fuse for their C common terminal. For example, C3 is common to Y14–Y17.

If one output is intermittent, isolate the field supply before checking the contact with a multimeter. If the load is a coil, inspect the suppression component too.

If the sensor detects a target and the X LED stays off, check the PNP or NPN sensor type, the 24 V DC supply and the S/S connection. Check the input state in the programming software as well.

Before removing the CPU, save the original project, module order and settings for COM2 and COM3. If communication drops when the machine starts, inspect cable routing and panel grounding.

Related PLC models

DVP60ES200T • 36 inputs and 24 NPN transistor outputs. DVP60ES200RE • Ethernet, 36 inputs and 24 relay outputs. DVP40ES200R • 24 inputs and 16 relay outputs. DVP80ES300R • ES3 CPU with 40 inputs and 40 relay outputs. For new panels, also review the I/O and communication options on Derell B Series PLCs.