Delta DVP64EH00R
Delta DVP64EH00R – EH PLC with 32 inputs and 32 relay outputs
The Delta DVP64EH00R is a first-generation Delta DVP-EH PLC main unit with a 100–240 V AC supply, 32 digital inputs and 32 relay outputs. This 16K-step class CPU can read sensors, sequence conveyors and switch valves or contactors in multi-station machinery.
Input addresses and field wiring
The built-in digital inputs use addresses X0–X37 and the outputs use Y0–Y37. The addresses are octal. Check the 24 V DC input circuit and S/S common when wiring inductive sensors or limit switches. Match the S/S connection to the PNP or NPN sensor circuit.
For high-speed counting with an incremental encoder, check the counter mode, X terminals and signal frequency together. Input circuits vary across the EH family. For example, the 5 V differential line-driver diagram for the DVP32EH00M applies to that model.
Relay output load ratings
Delta rates the relay outputs at 2 A per point and 5 A per common group, with a response time of about 10 ms. Identify each C common on the terminal diagram. An external supply powers the load through the corresponding common. Check the load type and inrush current against the ratings.
Use suitable fusing and the load maker’s specified suppression for coils. A suitable flyback diode on a DC coil limits the voltage spike when the coil switches off. The Y terminals switch loads on and off through relay contacts. For pulse positioning, select a CPU with a suitable pulse output.
Programming software, cable and communications
Use WPLSoft to read, edit and monitor an existing ladder program online. If your ISPSoft version supports the first-generation EH target, create a serial channel in COMMGR. Select the original EH PLC project target and save a copy of the original project before conversion.
Programming uses COM1 RS-232, 8-pin mini-DIN. Connect a DVPACAB2A30 Delta PLC cable between the PC’s DB9 serial port and the PLC. On a USB-equipped PC, add a suitable USB-to-RS-232 adapter. Install its driver, select the Windows COM port and match the existing serial settings.
COM2 RS-485 is the built-in communications port for field devices. On a Modbus RS-485 line, match the station address, serial settings and ASCII or RTU mode at both ends.
Related Delta models
The DVP64EH00T offers the same 32 inputs and 32 outputs with transistor switching. The DVP48EH00R has 24 inputs and 24 relay outputs. The DVP64EH00R2 belongs to EH2 and the DVP64EH00R3 to EH3. Both have 32 inputs and 32 relay outputs. Before swapping a CPU, check terminal assignments, expansion modules, memory areas and the software target together.
Editor’s Note
Read the full nameplate. When buying used, ask for photos of the full code, supply rating and output terminals. The R, R2 and R3 suffixes matter when choosing a spare.
Check the contact as well as the LED. Test each output with a suitable load in both states. If a load stays on after the output command turns off, the contact may be welded.
Check the common when a group fails. If several Y outputs stop working together, start with the C terminal, shared load supply and group fuse.
Back up before battery work. Save the program, required retained values and serial settings. Test COM1 and COM2 individually.
If the fault appears when a coil energises, check grounding, control cable routing and electromagnetic interference. Measuring at the PLC terminal helps isolate field wiring faults.
Internal references and PDFs
Related topics · Delta DVP PLC series · Delta PLC · Used Delta equipment
External references
Delta DVP-EH instruction sheet, 5011621601-EHE1 · Delta DVP-PLC programming manual, §2 · Delta WPLSoft and ISPSoft explanation