Delta DVP48EH00R

Delta DVP48EH00R PLC | 24 Inputs, 24 Relay Outputs

The Delta DVP48EH00R is a 100–240 V AC PLC CPU in the original DVP-EH series. It has 24 digital inputs at 24 V DC and 24 relay outputs. In conveyor, filling or assembly systems, it can read inductive sensors and photoelectric sensors and control valves, interposing relays and contactors through suitable load circuits.

Inputs, relay outputs and cabinet wiring

The onboard PLC inputs and outputs use octal addresses. Inputs run from X0–X27 and outputs from Y0–Y27. Check the S/S common against the sink/source diagram for your PNP or NPN sensors. Delta lists 16K program steps for the EH family and a 174 mm body width for the 48EH.

Delta’s 2006 EH instruction sheet gives 2 A per output and 5 A per common for the relay contacts. The EH selection table lists 1.5 A per output. When sizing the load, verify the rating for the unit’s hardware revision, load voltage and load type. Use the wiring diagram to check suppression for contactor and valve coils, the common groups and the fuse. For a pressure or level transmitter, select an analog input module for the signal type.

Encoder counting and load switching

For length measurement with an incremental encoder, select the A/B input pair from the original EH counter table. Check the signal level, counting mode and maximum frequency together. The R model uses Y-terminal relay contacts for on/off load switching. For a drive that requires high-speed pulse output, choose a transistor-output CPU or positioning module rated for the required pulse channels and frequency.

Programming software and cable

Use WPLSoft to read the Ladder program from the PLC to the PC and save a backup. Select DVP-EH as the CPU family for the programming connection. If you use ISPSoft, verify the first-generation EH target in your installed version and start the serial connection in COMMGR.

Connect the PC to COM1 RS-232 with the Delta DVPACAB2A30 cable. If the PC has no DB9 serial port, use a compatible USB-to-RS-232 adapter at the PC end and select the assigned Windows COM port. See Delta PLC cables for other connection options.

COM2 RS-485 is available for industrial communications. For Modbus RTU, match the station address, baud rate, parity and stop bits at both ends. Before replacing the CPU, record the serial settings and the part number of any installed function card.

Related Delta models

DVP48EH00T is the first-generation transistor-output model with the same I/O count. DVP40EH00R provides 24 inputs and 16 relay outputs. DVP48EH00R2 belongs to EH2 and DVP48EH00R3 belongs to EH3. Both have 24 inputs and 24 relay outputs. Compare program instructions, special registers, terminals and installed cards before replacing the CPU.

Editor’s Note

When buying used, ask for clear photos of the side label and removable terminal blocks. Check whether the model code ends in R, R2 or R3.

Back up the program and required data through COM1. If BAT.LOW is on, follow Delta’s battery procedure.

When a Y LED lights, check that the contact actually switches a suitable test load. Disable machine motion for the test.

If several outputs in one group fail together, check the common supply and terminal contact before checking individual relays.

If the count becomes erratic when a variable-frequency drive starts, inspect the cable route, sources of electromagnetic interference and cabinet grounding.

Related topics, internal references and PDF files

Delta DVP PLC files · Delta DVP-EH · Delta DVP-EH2 · Delta DVP-EH3

External references

Delta DVP-EH instruction sheet (2006, EN PDF) · Delta DVP technical selection guide (EN PDF) · Delta DVP-PLC programming manual (EN PDF)