6ES5 951-7LD12
Siemens SIMATIC S5 6ES5 951-7LD12 PS 951 Power Supply
The Siemens 6ES5 951-7LD12 is a PS 951 rack power supply for the SIMATIC S5 S5-115U and S5-115H. Siemens lists a 120/230 V AC input and a 5 V DC main rack output. It is rated at 7 A without a fan and 15 A with the appropriate fan assembly. The same table identifies the 7LD12 as the galvanically isolated version.
The supply powers the CPU, programmer interface and I/O control electronics in the S5-115U rack. When calculating the 5 V load, use the current rating of the installed CPU 943, CPU 944 or other S5 modules. Follow the cabinet drawings for the separate load circuits that feed field sensors and actuators.
AC input selection and output rails
Check the front-panel voltage selection against the unit label and the AC supply available in the cabinet. Siemens lists 5.2 V DC and 24 V DC auxiliary rails alongside the main 5 V DC output. The PS 951 range also includes 24 V DC input models such as the 7ND12 and 7ND41. Their 24 V input serves a different purpose from the 7LD12’s 24 V auxiliary rail.
Fan and rack requirements for 15 A
Siemens specifies fan-assisted operation for a rack load above 7 A. Check the fan’s own supply, its size and the airflow path. The 115/230 V AC fan assembly and 24 V DC fan assembly need different feeds. Use the full chassis number to check the fan mounting on racks such as the CR 700-1, CR 700-2 and CR 700-3.
Related PS 951 versions and battery backup
The 7LD11 and 7LD21 are closely related AC-input versions. Check the nameplate, rack connections and battery arrangement even when two units share the same output rating. For example, the 7LB21 is an AC-input 3 A supply, and the 7NB21 is a 3 A supply with a 24 V DC input.
The 7LD12 product listing specifies that the backup battery is not included. If the S5-115U rack uses an IP 244 3AA13 or IP 244 3AA21, Siemens requires a battery-backed slot and 7LD12 hardware version 2 or later. The same manual gives separate version requirements for the 7LB14 and 7NB13. Read the hardware version from the supply label.
Editor’s note
Before buying a spare, ask for photos showing the 7LD12 suffix, hardware version and front voltage selector.
With cabinet power isolated, have qualified maintenance staff check the AC input selection, mains connections and protective earth against the cabinet drawings.
If the 5 V load is above 7 A, verify the fan supply and airflow. Record the fan assembly and load current used in the test.
Verify the STEP 5 project backup before removing the supply. On racks with IP 244, record the battery-backed slot and the power supply hardware version before putting the rack back into service.
When buying used, ask for a 5 V reading under load, the selected AC input and the test duration. If you have a unit to sell, email a label photo, quantity, known condition and asking price to otomasyonavm@gmail.com.
OtomasyonAVM resources and PDFs
+ SIMATIC S5-115U CPUs and racks
+ SIMATIC S5 manuals and PDF archive
+ Siemens S5-115H system manual · PS 951 family, p. 3-38 (EN)
Related topics
+ 6ES5 951-7LD21 AC-input PS 951
+ 6ES5 951-7ND12 DC-input PS 951
+ 6ES5 981-0HA11 AC fan assembly
Browse SIMATIC S5
+ Used Siemens automation equipment
External references
+ Siemens S5-115H manual · 7LD12, Table 3.7, p. 3-38 (DE)
+ Siemens IP 244 / FB 162 manual · battery-backed slot and PS 951 version, p. 2-14 (EN)