6ES5 095-8ME03
Siemens SIMATIC S5-95U PROFIBUS-DP Master — 6ES5 095-8ME03
The Siemens 6ES5 095-8ME03 is a compact SIMATIC S5-95U PLC with a 24 V DC supply and an integrated PROFIBUS-DP master interface. It has 16 digital inputs and 16 digital outputs on board. Siemens lists a memory module in the scope of supply for this order number.
The controller reads machine sensors on its local inputs and exchanges cyclic data with remote ET 200 stations over PROFIBUS-DP. It can, for example, read a position signal and send a valve command to the same remote station. When selecting a spare for the PROFIBUS network, match the order number and confirm that the CPU is assigned the master role.
DP network, station limits and addressing
The Siemens S5-95U DP master manual specifies 9.6 kbit/s to 1.5 Mbit/s and up to 16 DP slaves. The linear DP address space is 128 input bytes and 128 output bytes. Each station is limited to 32 bytes in each direction. When adding an ET 200U interface such as the IM 318-B 6ES5 318-8MB12, check its operating mode and actual I/O lengths against the COM PROFIBUS project.
The DP socket is a 9-pin D-sub RS-485 interface. Siemens assigns line B to pin 3 and line A to pin 8. Use a suitable PROFIBUS connector. Check termination at both ends of the segment and confirm the addresses and baud rate across the PROFIBUS network.
Onboard inputs, outputs and counters
The 40-pin front connector carries the local 24 V DC digital inputs and 24 V DC digital outputs. In STEP 5, the inputs are addressed at I 32.0–I 33.7 and the outputs at Q 32.0–Q 33.7. The rated local output current is 0.5 A per channel.
The eight onboard analog inputs accept 0–10 V. The single analog output provides 0–10 V or 0–20 mA, depending on the connection. The two built-in counter inputs are rated at 5 kHz for A and 2 kHz for B.
STEP 5 and DP configuration backup
Connect the programming device to the separate 20 mA TTY PG port with a suitable S5 programming cable. Back up the STEP 5 application and the COM PROFIBUS station configuration separately. The Siemens DP master manual specifies a special 32 KB EEPROM for both sets of data. The DP configuration is transferred over PROFIBUS-DP with the memory module installed in the CPU.
Power, mounting and local expansion
The CPU mounts on a 35 mm DIN rail. Siemens lists the PS 931 24 V DC power supply as one supply option for this family. Use S5-100U I/O modules and S5 bus units for local expansion. Local expansion I/O and remote PROFIBUS I/O are addressed separately.
BF diagnostics and related order numbers
With RUN on and BF flashing, the Siemens manual indicates that at least one DP slave is unreachable. When troubleshooting, first check the station’s supply, address and bus connector. The STEP 5 application can read DP diagnostics with FB 230.
The 6ES5 095-8ME01 and 6ES5 095-8ME02 are other order numbers in the master family. The 8MD03 is the DP slave variant. Check the network role and project requirements when considering the 8MB03 PROFIBUS variant or the 8MA05 standard compact unit.
Editor’s note
Identification. Photograph the full 6ES5 095-8ME03 order number and the label on the fitted EEPROM before ordering a spare.
Separate backups. Save the STEP 5 application and the COM PROFIBUS project before removal. Record each station address and its DP data lengths.
Front connections. Label the digital front connector, analog socket, PG lead and DP plug separately.
BF check. If local I/O still works while BF flashes, start with DP station diagnostics. Identify the unresponsive station before reloading the bus configuration.
First run. Check local inputs and outputs first, then verify each DP station. Confirm remote outputs at their stations even when the CPU indicates RUN.
OtomasyonAVM resources and PDFs
SIMATIC S5 CPU family · ET 200 remote I/O stations · S5-95U system manual access page
OtomasyonAVM SIMATIC S5 PDF archive
Related topics
S5-95U DP master 8ME01 · S5-95U DP master 8ME02 · ET 200U IM 318-B · Siemens PROFIBUS connectors
Back to the S5 range
S5-90U–115U CPU pages · Siemens SIMATIC S5 · S5 communications modules
If you have an S5-95U to sell, send a label photo, quantity and operating condition to otomasyonavm@gmail.com.
Siemens and external references
Siemens 6ES5 095-8ME03 data sheet · Siemens ST 50 — 8ME03 ordering table (Russian)
Siemens ET 200 — S5-95U DP master hardware, family manual covering 8ME01 · COM PROFIBUS — transferring the DP configuration to the 32 KB EEPROM