Siemens 6ES5 243-1AB12 is the IP 243-1AB analog input configuration for SIMATIC S5 systems. This S5 analog module has a 12-bit A/D converter with eight selectable channels and four analog conditioning circuits. A single analog input conversion takes a maximum of 35 µs.

The 1AB configuration has no D/A converters, digital inputs/outputs, comparators or P-controller circuits. When reviewing analog I/O functions or digital input capabilities, use the 1AB configuration table rather than the specification of the fully equipped 1AA.

Input ranges and signal routing

The voltage input range is jumper-selectable as ±5 V, ±10 V or 0–10 V. When using a 0–10 V sensor, match the module range and jumper arrangement to the transmitter output.

Check the source of the analog signal too. Analog sensors and pressure transmitters can represent the same physical quantity through different electrical interfaces. Confirm the actual output type before wiring.

Where temperature signal converters or other analog signal conditioners are installed, record the field output, conditioning path and voltage reaching the ADC separately. The soldered signal links on the board form part of that measurement path.

Reading values with STEP 5

The reading sequence is select channel → start conversion → read result. The PLC program can use FB 160 (PER:ANL) for the IP 243. During troubleshooting, first confirm that the selected channel matches the field wiring.

For direct access with module base address A, write the channel selection to byte A+7, start conversion by writing to A+6, and read the result from peripheral word A+6. 35 µs is the single-conversion time; reading all channels also involves program instructions and the PLC cycle.

Supply, reference and field wiring

The external supply is 24 V DC, with a permitted range of 20–30 V DC. Signals are not galvanically isolated. Check grounding and the common reference; investigate electromagnetic interference together with the measurement wiring and cabinet connections.

When checking S5 connectors and cables, verify the 0–10 V versus 4–20 mA interface. The specified ADC ranges are voltage ranges. Before connecting a current signal, establish a suitable current-to-voltage conversion arrangement.

System compatibility and installation

With the appropriate installation, IP 243 can be used in S5-115U, S5-135U and S5-155U systems. S5-115U requires an adapter casing. Follow the rack and slot tables for the Siemens S5 system; physical fit alone does not establish the available functions.

Editor’s note

Start with the complete suffix: this module is 1AB12. Do not expect the functions of a fully equipped IP 243 such as 1AA12. Keep a clear photograph of the original label beside you when choosing a spare; it saves a lot of avoidable confusion.

The signal links deserve close attention on this card. Photograph the original routing links, range settings and connections. Compare the replacement with the machine diagram before assuming its factory arrangement matches the application.

If a reading drifts or appears offset, leave the adjustment pots alone initially. Check the transmitter output, common reference and signal path into the ADC first. Changing a good adjustment to compensate for a wiring fault makes the eventual repair harder.

Go beyond a single-channel check. Test all eight ADC channels individually at low, middle and high voltage points. Test the conditioning paths separately as well. This makes it much easier to establish which section needs attention.

When buying a used analog module, ask for the test readings and jumper arrangement together where possible. A supply indicator alone cannot establish measurement accuracy. A short test record gives both buyer and seller something useful to work from.

OtomasyonAVM resources and PDFs

+ Browse our S5 analog module pages and Siemens S5 PLC overview for related system information.

+ Siemens S5 shared PDF archive and manuals. The IP 243 manufacturer manual and the record listing the exact order code are provided under external references.

Related topics

+ 6ES5 243-1AA12: the fully equipped IP 243 family. 6ES5 243-1AB11: an earlier code in the input-oriented 1AB family; check the revision and signal links separately.

+ 6ES5 243-1AC11: the 1AC configuration with D/A converters and no A/D converter. Account for this functional difference.

Browse SIMATIC S5

+ S5 analog modules · S5 function modules · SIMATIC S5

+ Siemens S5 PLC · Siemens second-hand equipment · Used analog modules

Siemens and external references

+ Siemens IP 243 Analog Module with FB 160 / FB 161 – English; 6ES5 998-0KF21, page 2-2 variant table and page 2-4 1AB block diagram.

+ Same manual – input ranges, A/D reading sequence, technical specifications and FB 160 programming.

+ Siemens S5-135U/155U System Manual – English; IP 243 rack and slot requirements, §4.1.

+ Historical UL E120869 record hosted by Siemens – English; exact 6ES5243-1AB12 order code.