GD100 / Goodrive100
INVT GD100 / Goodrive100 general-purpose AC drive
The INVT Goodrive100 (GD100) is a variable frequency drive for three-phase induction motors in fans, pumps, conveyors and similar machinery. INVT manuals describe V/f control and sensorless vector control. V/f can suit fan and pump loads. Consider vector control where the machine needs stronger torque response at low speed or tighter speed control as the load changes.
The manuals list -4 models from 0.75 to 15 kW in the three-phase 400 V class. For example, GD100-5R5G-4 is listed at 5.5 kW and 14 A rated output, and GD100-011G-4 at 11 kW and 25 A. When selecting a drive, check voltage class, output current and duty cycle alongside the motor’s rated power. Read the drive label for the supply and the motor nameplate for its connection. Single-phase and three-phase drives
Run command and speed reference
P00.01 selects whether the run and stop commands come from the keypad, terminals or communications. P00.06 and P00.07 select the A and B frequency reference sources. A machine can take its run command from panel pushbuttons and its speed reference from an analog signal. See three-wire control and sink/source inputs when reading the terminal diagram.
Read voltage, current, power, speed and rated frequency from the motor nameplate. The manual describes rotating and stationary auto-tuning under P00.15. Set up acceleration and deceleration ramps, preset speeds or PID control according to the application.
Deceleration, braking resistor and fault history
When a decelerating load drives the motor, regenerative energy can raise the DC bus voltage. If the application needs dynamic braking, use Appendix C.7 to check the exact model’s brake chopper arrangement, permitted braking resistor and duty cycle. A conveyor that stops repeatedly has different braking demands from a fan that stops occasionally.
Write down the alarm code and whether it appeared while starting, running at speed or stopping. P07.27 shows the current fault and P07.28 shows the previous fault. OL1 means motor overload and OL2 means drive overload. See section 6.2 of the GD100 manual for the fault table, and the VFD fault guide and overload guide for background.
INVT Studio and RS-485 Modbus
INVT lists GD100 in the serial connection support list for INVT Studio. See INVT VFD Software for software and version information. The drive uses Modbus RTU over two-wire RS-485. Check the station address, baud rate and frame settings in group P14. For a PLC or HMI connection, confirm register addresses and scaling in chapter 7 of the GD100 manual. The INVT Modbus address guide is a general reference.
GD100 manuals and related ranges
OtomasyonAVM’s document category is INVT VFD Documents. The Turkish and English manuals below cover the standard Goodrive100. For solar pumping see GD100-PV, and for the wire-drawing drive see GD100-03. Other general-purpose INVT ranges include GD20 and Goodrive200.
Editor’s note
If you’re sourcing a spare, take a clear photo of the label. Get the voltage suffix and rated output current in the shot along with GD100.
On a used drive, look at the fan, terminals and keypad. If it has been tested on a motor, ask what load and current it ran at.
If RUN is on but the motor hasn’t moved, check the speed reference first. The run command and speed reference can come from different places.
If the machine trips on stopping, record the code, stopping time and what the load was doing before you reset it. That record helps when assessing the braking resistor.
Save the parameters and terminal assignments before removing the old drive. A factory reset takes little time. Reconstructing how a machine has been controlled for years takes much longer.
Related topics
How a frequency inverter works · S-curve ramping · Current limiting · INVT fault codes
Browse INVT brand home › INVT VFD drives › INVT user manuals
External references
Goodrive100 operation manual (English PDF, 111 pages) · Model and current ratings · Fault diagnosis · RS-485 and Modbus · Braking system
Goodrive100 operation manual (Turkish PDF, 122 pages) · INVT Studio manufacturer information