Delta DVP32EH00M

Delta DVP32EH00M – DVP-EH PLC with Differential I/O

The Delta DVP32EH00M is a first-generation Delta DVP-EH PLC CPU powered by 100–240 V AC. It has 16 inputs and 16 outputs. Its 5 V differential encoder inputs and differential pulse outputs up to 200 kHz on two axes suit machine automation applications such as feeding, cutting and labeling.

5 V encoder inputs and 24 V field inputs

Inputs are addressed X0–X17 and outputs Y0–Y17. Addresses use octal numbering. For a differential line-driver incremental encoder, use the individual +/− terminal pairs on X0, X1, X4 and X5. These are 5 V DC inputs. Delta’s application example gives a 200 kHz limit for the counter using X0/X1. Check the frequency limit for your selected counting mode in the manual.

The other digital inputs accept 24 V DC field signals. When wiring an inductive sensor, photoelectric sensor or limit switch, check the S/S common and the PNP or NPN sensor type. For continuous measurements, use the distinction between analog and digital inputs to select a suitable module.

Two-axis pulse outputs and relay outputs

CH0 uses Y0/Y1 and CH1 uses Y2/Y3. Each address has its own +/− differential terminals. For position control, match the servo drive’s differential input level and pulse format to the PLC instruction. For a drive such as the Delta ASDA-B2, consult its pulse input diagram. The Y4–Y17 relay outputs serve auxiliary on/off circuits. Check the relay contact ratings when selecting the field load. If the signal is unstable, check protective grounding, twisted-pair wiring and possible sources of electromagnetic interference.

WPLSoft, ISPSoft and programming cable

Use WPLSoft or a version of ISPSoft that supports the first-generation EH CPU for PLC programming. Select DVP-EH as the target. Configure the ISPSoft connection in COMMGR. Back up the existing ladder program and retained data before making changes.

Delta specifies DVPACAB2A30 for COM1 (RS-232, 8-pin mini-DIN). If the PC has no serial port, use a USB-to-RS-232 adapter with its driver. Select the COM port assigned by Windows. See Delta PLC cables for other options.

COM2 (RS-485) can be used for industrial communication. For an existing RS-485 Modbus link, record the station address, baud rate and parity. For a Modbus RTU link to SCADA, read a known address after servicing to verify data flow.

Editor’s Note

Check the label and terminals together. When buying used, ask for the complete DVP32EH00M code and a close-up of the differential terminals.

Check the encoder circuit separately. Follow the 5 V wiring diagram for X0, X1, X4 and X5. Route 24 V field sensors to the appropriate standard inputs.

Test each axis on the bench. Check the differential pulse signal with a suitable instrument. Test the relay outputs with a suitable load.

Check the BAT.LOW indicator. Save the project and required retained data before battery service. Follow the replacement conditions in the manual.

Test the first move at low speed. Under safe commissioning conditions, check direction, homing and limit response.

Related Delta models

Among first-generation 32-point EH models, the DVP32EH00R is the relay version and the DVP32EH00T is the transistor version. The DVP32EH00M2 belongs to EH2 and the DVP32EH00M3 to EH3. Before replacing the CPU, compare input levels, output types, terminal layouts and project compatibility.

Internal references and PDF files

Delta DVP PLC PDF files · Delta DVP PLC programming manual, EH table (PDF) · Delta DVP PLC series · Used Delta products

External references

Delta DVP-EH wiring sheet, 2006 edition (PDF) · Delta DVP-EH output specifications, M-model note · Delta hardware FAQs, differential outputs and programming cable · Delta ISPSoft user manual (PDF)