Delta DVP32EH00M3
Delta DVP32EH00M3 | 16 inputs, 16 outputs and 2 differential pulse axes
The Delta DVP32EH00M3 is a 100–240 V AC main unit in the DVP-EH3 series with 16 digital inputs and 16 digital outputs. Four output points serve two differential pulse axes. Y4–Y7 and Y10–Y17 are the 12 relay outputs. In labeling or cut-to-length equipment, the PLC reads the encoder. The CPU runs the sequence and issues pulse commands to the drive.
Encoder inputs and high-speed counters
X0/X1 and X4/X5 form two differential high-speed counter channels rated up to 200 kHz. For an incremental encoder, check the A/B line-driver signals and the input specifications. X10/X11 and X14/X15 form two single-ended high-speed counter channels rated up to 200 kHz. Delta’s instruction sheet includes a separate wiring diagram for high-speed differential inputs.
The built-in PLC inputs and outputs use octal addresses X0–X17 and Y0–Y17. Before connecting an inductive sensor to a standard 24 V DC input, identify its PNP or NPN output and check the S/S terminal in the sink/source wiring diagram.
Differential pulse and relay outputs
The two high-speed pulse axes, rated up to 200 kHz, are CH0 Y0/Y1 and CH1 Y2/Y3. Each Y point has a positive and negative terminal. Match the pulse and direction signals to the instruction, the drive input and Delta’s wiring diagram. For example, look up the pulse inputs in the Delta ASDA-A2 manual. The servo drive powers the servo motor.
The relay contacts at Y4–Y7 and Y10–Y17 handle general switching. Check the external load supply and C0, C1 and C2 groups against the terminal diagram. Check the DIN rail layout and protective grounding during installation. For analog inputs, consider a compatible expansion module such as the DVP04AD-H3.
Programming software and cables
Read and back up the existing ladder program with WPLSoft. ISPSoft also supports the EH3 target. Configure the ISPSoft connection through COMMGR. Before writing the program, check the project CPU type and the motion instructions it uses.
For COM1 (RS-232), use UC-PRG020-12A with a USB-equipped PC or UC-MS020-01A with a native RS-232 port. Install the USB cable driver and select the COM port assigned by Windows. For Modbus over COM2 (RS-485), match the station address and serial settings. Delta PLC cable options
Related Delta models
The DVP32EH00MT retains two differential pulse axes and uses transistor outputs for general switching. The DVP32EH00R3 is the 16-input, 16-output relay model and the DVP32EH00T3 is the transistor model. The DVP80EH00T3 offers 40 inputs and 40 transistor outputs. For a replacement, check the signal interface, terminal layout and project compatibility.
Editor’s note
When buying used, zoom in on the nameplate. The M3 and MT differ at the general-purpose load outputs.
Before removal, save the PLC program, encoder channel settings, drive pulse mode and electronic gearing values.
Test the two differential axes and the relay contacts the machine uses separately on the bench.
If the encoder count is erratic, check the A/B pairs, shielding and signal level first.
Make the first move at low speed under safe test conditions. Check direction and the distance traveled per command.
PDFs and internal references
Delta DVP PLC files · Delta DVP-EH3 · Delta DVP PLC series
External references
Delta DVP-EH3 instruction sheet (PDF) · Delta 2020 hardware revision · Delta DVP catalogue · Delta Cable Selection Guide, section 1.10.1