6ES5 955-3LF12

Siemens 6ES5 955-3LF12 SIMATIC S5 power supply

The 6ES5 955-3LF12 is an isolated SIMATIC S5 955 power supply used in S5-135U, S5-150U and S5-155U systems. Siemens lists a selectable 120/230 V AC input in the 135U and 155U manuals and rates the rack backplane output at 5.1 V DC ±0.5%, 40 A. The auxiliary outputs share a 2.8 A current limit.

In a SIMATIC S5 installation, this unit supplies the CPU and the modules on the central backplane. Siemens pairs it with the 6ES5 135-3UA21 and 6ES5 155-3UA11 central racks. The S5-150U 6ES5 150-3SB61 manual lists the 3LF11 and 3LF12 under 110/220 V AC, 50 Hz. Match the replacement unit’s nameplate and selector position to the cabinet supply.

Mains input, fuses and rack connectors

The 135U and 155U technical tables specify an input frequency of 48–63 Hz. With cabinet power isolated, check the voltage selector, the PE conductor and the protective earth bond between the front plate and the rack. The F107 input fuse is rated 6 A fast-acting. The F255 24 V output fuse is rated 4 A fast-acting. Both fuses are 250 V, 6.3 × 32 mm.

At the rear, X1 is the 8-pin power connector. The 37-pin X2 carries signals and auxiliary supplies. Use the rear views in figures 14 and 15 of the 155U manual to identify the S5 connectors.

24 V and 15 V auxiliary supplies

The 24 V DC backplane output is rated 2.8 A, and the front 24 V DC enable output is rated 0.4 A. The optional submodule supplies 15 V DC at 2 A for S5 communications processors such as the CP 535 or CP 143. Keep the sum of the three auxiliary output currents within 2.8 A. Trace any external 24 V supply to the field digital inputs and digital outputs separately on the cabinet drawing.

Identifying nearby 955 variants

The 3LF11, 3LF41 and 3LF42 have separate 955 order numbers. The 3NF11 is a 40 A variant with a 24 V DC input. The 3LC14 is an AC-input 18 A model. Parts listings also cite the EU 185U for the 3LF12. The 6ES5 185-3UA11 listing, for example, identifies an 18 A rack. Match both the rack and the power supply order numbers when sourcing an expansion-rack spare.

Fan, battery and supply indicators

Fan Fault signals loss of airflow from one or both axial fans. With F-R closed, a fan fault shuts down the rack supply. Record the 5 V, 15/24 V Bus and front 24 V indicators separately during PLC fault finding. If only an expansion rack is affected, check its supply and the connection between the interface modules.

If Batt. Low is lit, verify the STEP 5 project backup before a planned shutdown. Identify what is held in CPU RAM and what is stored on the S5 memory card. On the 3LF12, Siemens documents battery fault signalling through RR-LL from hardware version 5 onward.

Editor’s note

Before ordering a spare, record the 955-3LF12 nameplate, hardware version and full rack order number. Ask for a photo of both rear connectors.

Check the cabinet supply against the voltage selector before switching on. On a 150U, read the 110/220 V designation in the cabinet documentation alongside the unit’s own nameplate.

If the 5 V LED is on and the Bus LED is dark, focus on the auxiliary supply. Isolate power before checking F255 and the 15 V submodule, if fitted.

If Fan Fault lights, inspect both fans and the air path. Compare F-R with the setting recorded before removal and restore airflow before returning the rack to service.

For a used unit, ask for a test record showing the 5 V rail under load, both fans running and the status of the auxiliary outputs.

OtomasyonAVM resources and PDFs

+ SIMATIC S5-135U 6ES5 135-3UA21 central rack · SIMATIC S5-150U 6ES5 150-3SB61 central rack

+ OtomasyonAVM SIMATIC S5 PDF archive

Related topics

+ 6ES5 955-3LF11 · 6ES5 955-3LF41 · 6ES5 955-3LF42 · 6ES5 955-3NF11

Browse Siemens S5

+ SIMATIC S5 power supplies · SIMATIC S5 · Used Siemens automation equipment

Selling this power supply? Send a nameplate photo, quantity, operating condition and asking price to otomasyonavm@gmail.com.

External references

+ Siemens S5-135U CPU 921/922 Manual · Table 1 identifies the rack. Section 6.2 gives the exact-model electrical ratings.

+ Siemens S5-155U CPU 946/947 Manual · Table 1 covers the rack pairing, section 5.4 covers X1/X2 and section 6.1 gives the ratings.

+ Siemens S5-150U Central Controller Manual (German) · Pages 13–14 give the 3LF11 and 3LF12 supply ratings.

+ Adegis 6ES5 955-3LF12 parts listing · Catalogue scope including the EU 185U.