6ES5 454-4UA14

Siemens 6ES5 454-4UA14 — 16-Channel 24 V DC Digital Output Module

The Siemens 6ES5 454-4UA14 is a 16-channel, 24 V DC digital output module for S5-135U/155U controllers in the SIMATIC S5 family. This S5 digital output module has a rated output current of 2 A per channel. It applies commands from the S5 central controller to field loads through transistor DC outputs.

Supply and combined load limits

The permissible load-supply range is 20–30 V DC. The manual specifies a maximum combined current of 4 A per four outputs and a 50% coincidence factor. All 16 outputs therefore cannot carry 2 A simultaneously. Galvanic isolation covers one group of 16 outputs; the four-channel fuse groups are not separate isolation groups.

Load type and output behaviour

For DC loads such as relay and contactor coils, assess switching conditions alongside operating current. The manual gives a 10 mA–2 A output-current range and 1 mA maximum OFF-state residual current. Resistive and inductive loads must not be assigned the same switching-frequency allowance.

F+/F− enable input and H+ fault output

The module has a 24 V DC F+/F− enable input. With jumper X20 fitted, the enable input is active; this is the factory setting. During PLC input/output checks, assess this enable condition together with the program command.

H+ provides a common fault signal when an output is short-circuited. Limited to 10 mA maximum, this signal can be monitored by a suitable digital input; it is not a field-load supply output.

UA14 fusing and short-circuit indication

The 454-4UA14 requires one 7 A fast fuse per four outputs. Do not confuse this fuse selection with the 6.3 A slow fuse specified for the 454-4UA13. A red short-circuit indicator covers a four-output group; inspect that group's wiring and loads together.

Front connector and mechanical arrangement

The board is 20 mm wide, but the ST 50 catalog requires a double-width front connector because of the current rating. Screw-terminal examples in this connector family are the 6ES5 497-4UB12 — 42-pin and 6ES5 497-4UB22 — 25-pin. Select connectors and cables against the existing terminal diagram and check available space in the S5 rack.

Fault finding and replacement

During PLC debugging, first check the command, F enable condition and the affected group's L+ supply. Interpret multimeter readings together with behaviour under load. Inspect grounding and cable routing when assessing noise immunity. Work on modules and front connectors with both PLC and field supplies disconnected.

Comparison with related models

The 6ES5 453-4UA12 also has 16 outputs rated at 2 A, but provides individual output isolation. The 6ES5 451-4UA14 is a 32-output, 24 V DC/0.5 A model. The 6ES5 454-7LA12 belongs to the S5-115U/F hardware family. Similar electrical ratings alone do not establish mechanical or wiring compatibility.

Editor's note

Start by adding up the load on each group of four outputs. A 2 A channel rating does not give every channel permission to run at full load together. Reading the group limit carefully helps the board last.

If all outputs stay quiet, give the board a fair check. The F enable input and X20 setting also matter. Photographs of the old working wiring and jumper position are useful here.

Keep the complete suffix in view when replacing a fuse. The UA14's fast fuse and the UA13's slow fuse are different selections. Use the specified type, rather than whichever happens to be on the bench.

A slim board does not necessarily take a slim front plug. Check the double-width connector requirement together with the existing cable's terminal arrangement.

Where possible, test a used board under load across all four output groups. Keep the result with the S5 system information so the next service starts with a useful record of each group's behaviour.

OtomasyonAVM resources and PDFs

+ Start with the OtomasyonAVM S5 PDF archive.

+ For exact UA14 specifications and wiring, see S5-135U/155U System Manual, 8-54–8-55. Connector and comparison information appear in ST 50, 4/39–4/42.

Related topics

+ 454-4UA13 · 453-4UA12 · 451-4UA14 · 454-7LA12.

+ 497-4UB12 front connector · 497-4UB22 front connector · S5 cables and connectors.

Browse SIMATIC S5

+ S5 digital output modules · SIMATIC S5 central controllers · Siemens S5 main page.

+ Used Siemens automation equipment.

Siemens and external references

+ Siemens S5-135U/155U System Manual — C79000-G8576-C199-07: pages 8-54–8-55, PDF pages 368–369; UA14 column, load limits, fusing, F/H signals and X20.

+ Siemens ST 50 Catalog — 1998: pages 4/39–4/42; technical comparison, double-width connector requirement and wiring diagrams. An externally archived copy of the manufacturer catalog.

+ CSA Certificate 1232105 — Siemens S5: PDF page 9; exact 454-4UA14 entry with 16 outputs, 24 V, 2 A and a 16 A total-load rating. Documents are in English.